3.4.4 Display of each panel device in operation
Be sure to check at times to see if gauges or each component of the unit are properly working, or if
there is any air-leak, oil-leak, water-leak or fuel-leak etc. During normal operation, each indication of
instruments is shown in the table below.
Refer to the table for daily checks.
The above table gives standard values. They may vary slightly depending on the operating
conditions and other factors.
Operating
condition
Before startup
(CONTROL
POWER switch set
to
position)
Starting unloaded
operation
Unload
Full load
Operating
condition
Before startup
(CONTROL
POWER switch set
to
position)
Starting unloaded
operation
Unload
Full load
※1: The display will switch. For details, see 3-1.
※2: This lamp will be OFF in 0 to 10 seconds, (varying upon ambient temperature.)
※3: This lamp will be OFF in about 2 seconds.
3. Operation
Air pressure gauge
―
About 44psi (3bar)
116 to 131psi
(8 to 9bar)
58 to 100psi
( 4 to 6.9bar)
GLOW
CHARGE
●
OFF
ON
※2
●
●
OFF
OFF
●
●
OFF
OFF
●
●
OFF
OFF
Indicator lamp
ENGINE
FUEL
ERROR
●
OFF
※3
●
OFF
ON
Changes
●
depending on
OFF
the remaining
quantity
●
OFF
3-13
※1
Digital monitor
(For engine speed)
0
Approx. 1,250min
-1
Approx. 1,250min
-1
Approx. 2,400min
-1
RESIDUAL
ERROR
PRESSURE
CODE
●
OFF
OFF
●
OFF
OFF
●
OFF
OFF
●
OFF
OFF
●
※3
●
●
●