2.3 Installation conditions

Be sure to use this machine in the following operating environment. If you use the machine not in
the conditions stated following, it may causes serious breakdown.
Ambient temperature ------ 5°F to 104°F (-15℃ to +40℃)
Humidity ----------------------- Less than 80%
Altitude ------------------------- Lower than 4,921ft above sea level
Allowable tilt angle --------- 15° or less
The machine has to be parked horizontally on a level place. To install this machine on a slope, set
it at a right angle to the slope.
The machine has to be installed in the environment where fresh air is always available,
temperature is low and ambient air is dry as much as possible.
If more than two machines are placed parallel in operation, keep enough distance so that exhaust
air from one machine does not affect the other one.
Also, a machine has to be installed in the environment where fresh air is always available.
Keep enough space around the machine for inspection and maintenance access.
Caution Exhaust gas
Exhaust pipe
Exhaust gas
×
Private house
2. Installation
Exhaust gas can cause death or serious injury
upon inhalation. Avoid using the machine in an
insufficiently ventilated building or tunnel.
Do not position the exhaust gas outlet in direction
of a person or a house.
PC002
When installing the machine in a tunnel or the like,
Use an air blower
ensure a supply of fresh air and provide adequate
for taking in ai
ventilation.
Be sure to place the exhaust pipe in an outdoor
location, so that no exhaust gas will be leaked
from any pipe seam.
A160725
Do not position the exhaust gas outlet in the
direction of a house.
Because the exhaust gas from the engine is
×
poisonous, avoid positioning it in the direction of
passers-by.
A130116