Hokuetsu AIRMAN PDS185S-6EZ1 Instruction Manual page 15

Engine compressor
Table of Contents

Advertisement

2.3.1 Service valve
Bore of service valve:20A(R3/4B)×2
Cautions of hose attachment and removal
TR0088
TR0303
Operation with discharge port (compressed air supply port) opened is prohibited
D003
2. Installation
[Taper male screw]
Piping or the hose from this machine service valve should use what can
be borne enough for the safety valve set pressure of this machine.
Please connect piping or a hose to this machine service valve firmly
before operation and during operation.
If the connection is loose, there is a possibility of piping or a hose
separating and getting seriously injured.
Please remove after closing the service valve and relieving remaining
pressure. If pressure remains, there is a possibility of the hose whipping,
causing damage and possibly injury.
In order to use it safely, please read the handling of the work tools often
used.
Do not operate the machine with service valves and relief valve open
unless air hoses and/or pipes are connected. High-pressurized air blows
out and its air pressure could cause injury to the people nearby.
When the machine has to be unavoidably temporarily operated with its
port open, be sure to mount a silencer to reduce noise and wear protective
materials such as earplugs to prevent damage to hearing.
2-5
A220064

Advertisement

Table of Contents
loading

Table of Contents