ActiveScale™ P100E3 Installation Guide
Upon first login, the ActiveScale SM Welcome screen appears.

Figure 4-4. ActiveScale SM welcome screen

4.12 Post CBWInstructions

Remove the factory installation SSH keys by running following bash commands:
Note: This should be run on all three nodes again.
sudo su - marvin
grep -v 'factory-install-key$' /home/marvin/.ssh/authorized_keys > /home/marvin/.ssh/authorized_keys_new
mv /home/marvin/.ssh/authorized_keys_new /home/marvin/.ssh/authorized_keys
To configure SNMP follow the ActiveScale_OS_Administrator_Guide instructions section 8.20 Configure
SNMP traps or polling
To configure syslog streaming follow the ActiveScale_OS_Administrator_Guide instructions section 8.31
Enable or disable syslog streaming
When you have reached this phase, you have an operational P100E3 setup.You can log in the ActiveScale
Management GUI for administrating the system. The system can be used for S3 operations.

4.13 VM Installation

P100E3 Converged Node Architecture Installation using an USB flash drive with ActiveScale ISO
These instructions apply to the P100E3 Converged Node Architecture setup. This is an entry level
ActiveScale system consisting out of 3 nodes. We will bootstrap the install of all three nodes using an USB
Flash Drive.