Tescom TEOS 300RT User Manual

10-40 kva
Hide thumbs Also See for TEOS 300RT:

Advertisement

Quick Links

TEOS 300RT
10-40 kVA
3 Phase In – 3 Phase Out
USER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TEOS 300RT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tescom TEOS 300RT

  • Page 1 TEOS 300RT 10-40 kVA 3 Phase In – 3 Phase Out USER MANUAL...
  • Page 3 Please comply with all warnings and operating instructions in this manual. This equipment should only installed, serviced, maintained qualified personnel. Do not operate this unit before reading through all safety information and operating instructions carefully. Disclaimer We assume no responsibility or liability for loss or damages, whether direct, indirect, consequential or incidental, which might arise out of the use of such information.
  • Page 4: Table Of Contents

    Table of Contents 1. Safety and EMC instructions ......................... 1 1-1. Transportation and Storage ....................1 1-2. Preparation ........................1 1-3. Installation ........................1 1-4. Connection Warnings ....................2 1-5. Operation ........................... 3 1-6. Standards ........................... 3 2. Installation and Operation ........................4 2-1.
  • Page 5: Safety And Emc Instructions

    1. Safety and EMC instructions All safety instructions in this document must be read, understood and followed. 1-1. Transportation and Storage Please transport the UPS system only in the original packaging to protect against shock and damage. The UPS must be stored in the room where the temperature is well regulated. Ambient temperature should not exceed 40°C.
  • Page 6: Connection Warnings

    1-4. Connection Warnings • There is no standard backfeed protection inside of the UPS. However, there are relays on the Input to cut off line voltage and while the neutral is still connect to UPS. Input Rly Main Input Rly Input Main Input...
  • Page 7: Operation

    1-5. Operation Do not disconnect the grounding/earthing conductor cable on the UPS or the building wiring terminals under any circumstance. The UPS system features its own, internal current source (batteries). The UPS output sockets or output terminal blocks may be electrically live even if the UPS system is not connected to the building mains/live wires.
  • Page 8: Installation And Operation

    2. Installation and Operation These series came with two VAC systems: 208V and 400V. Please refer to the following table. VAC System Model Type 208V LV 5KL/7.5KL/10KL/15KL/20KL Long-run model 400V HV 10KL/15KL/20KL/30KL/40KL We also offer optional parallel function for both models upon request. The UPS with parallel function is called the “Parallel model”.
  • Page 9: Wiring Terminal View

    2-2. Wiring Terminal View Diagram 1: Front panel Diagram 2: HV 10KL/LV 5KL Rear Panel Diagram 3: HV 15KL/HV 20KL/ LV 7.5KL/LV 10KL...
  • Page 10: Single Ups Installation

    Diagram 4: HV 30KL/ LV 15KL Diagram 5: HV 40KL/LV 20KL 1. Power switch 2. External maintenance bypass switch port 3. USB communication port 4. Emergency power off function connector (EPO connector) 5. Share current port (only available for parallel model) 6.
  • Page 11 Make sure that the mains wire and breakers of the building are rated for the capacity of the UPS to prevent electric shock or risk of fire. NOTE: Do not use the wall receptacle as the input power source for the UPS, as its rated current is less than the UPS’s maximum input current.
  • Page 12 HV 10KL/LV 5KL/ HV 15KL/HV 20KL/HV 30KL/LV 7.5KL/LV 10KL/LV 15KL terminal block wiring diagram HV 40KL/LV 20KL terminal block wiring diagram TO UPS BAT+ PBAT TO UPS BAT N NBAT TO UPS BAT- Battery wires connection schematic NOTE 1: Make sure that the wires are connected securely with the terminals. NOTE 2: Please install the output breaker between the output terminal and the load, and the breaker should have leakage current protective function if necessary.
  • Page 13: Ups Installation For Parallel System

    NOTE: Set the battery pack breaker in “OFF” position and then install the battery pack. ● Pay special attention to the rated battery voltage marked on the rear panel. If you want to change the numbers of the battery in a chain, make sure you modify the UPS setting accordingly. Connection with wrong battery voltage may cause irreversible damage of the UPS.
  • Page 14: Software Installation

    HV 40KL/LV 20KL wiring diagram of parallel system 2-5. Software Installation For optimal computer system protection, install UPS monitoring software to configure UPS shutdown operation.
  • Page 15: Operations

    3. Operations 3-1. Button Operation 1) Before operation, make sure that the two strings of batteries are connected correctly in order of ”+,GND,-” terminals and the breaker of the battery pack is at “ON” position (only for long-run model). 2) Press the “ ”...
  • Page 16 3-2-1. Main screen Upon powering on, the LCD will start initialization approximately few seconds as shown below. After initialization, the main screen will display as shown below. After touching the icon, it will show five icons in center to represent five sub-menus: Control, measure, setting, information, data log.
  • Page 17 Touch icon will return back to main screen no matter it’s in any screen of any submenu. Enter or return Confirm YES DO ON/OFF UPPS ON/OFF UPS Enter or return Confirm YES DO BATT TEST HOME CONTROL BATT TEST Enter or return Confirm YES DO MUTE ALL MUTE ALL Enter or return...
  • Page 18 TURN ON UPS TURN OFF UPS Battery Test  It will show “Start Battery Test” if the UPS is not in test. Touch “Yes” to start battery test. Then, it will start battery testing. After few seconds, battery test result will show on the screen. Touch “Back” to return to main screen immediately or “No”...
  • Page 19 LCD Change  When LCD is in “Rack Display”, if you touch “LCD Change” icon, it will pop-up “Tower Display” window. When LCD is in “Tower Display”, if you touch “LCD Change”, it will pop-up “Rack Display” window. Touch ”Yes” icon to change LCD Display. Touch “No”...
  • Page 20 3-2-3. Measure screen Touch the icon to enter measure page. Touch the icon to browse information. Touch the icon to return to main screen. Touch the icon to go back to previous menu. Measure screen page 1 LINE VOLT: The real time value of L1, L2 and L3 phase voltage, L1L2/L2L3/L3L1 voltage and input ...
  • Page 21 Measure screen page 3 INPUT W: L1, L2 and L3 input power in watt.  INPUT W (%): L1, L2 and L3 input power watt in percentage.  Measure screen page 4 INPUT VA: L1, L2 and L3 input power in VA. ...
  • Page 22 Measure screen page 6 OUTPUT VA: L1, L2 and L3 output power in VA.  OUTPUT VA (%): L1, L2 and L3 output power VA in percentage.  Measure screen page 7 INPUT CURR: L1, L2, L3 input current in Amp. ...
  • Page 23 Measure screen page 9 BUS Voltage: The real time value of DC BUS (P and N) voltage.  TEMP: Temperature of L1, L2 and L3 phases.  Measure screen page 10 Backup Time: Estimated discharge time.  BATT Voltage /Charging Current/Discharging Current: The real time value of DC related information. ...
  • Page 24 Setting screen GENERAL: It’s to set up basic information of the UPS. It’s not related to any function parameter.  ADVANCE: It’s required to enter password to access to the “ADVANCED” setting. There are two types of  authority, User and Maintainer. GENERAL USER PSSWORD:0000 ELECTRIC...
  • Page 25 General Setting Setting screen page 1 Language: Set the LCD language. There are three options: English, Simplified Chinese and Traditional  Chinese. English is default setting. Input Source: Select the input source. There are two options: Line (utility) and generator. Line is ...
  • Page 26 If you touch “Yes”, it will turn on the warning buzzer. The factory default setting is turn on the warning buzzer. All Mute:  Disable: When selected, the UPS will alarm when warning occurs. Enable: When selected, the UPS will NOT alarm when warning occurs. Mode Mute: ...
  • Page 27 Advance Setting Menu Page There are three sub-menus under “AdvanceUser” setting: ELECTRIC, BATT and OTHERS. ELECTRIC Electric Setting Page 1 Output VOL.: Select the output rated voltage.  If the UPS is HV system, there are four options, 208V, 220V, 230V and 240V. ...
  • Page 28 Electric Setting Page 2 Bypass at UPS off: Select the bypass status when manually turning off the UPS. This setting is only  available when “Bypass forbid.” is set to “Disable”. Enable: Bypass enabled. When selected, bypass mode is activated. ...
  • Page 29 L: Low voltage point for ECO mode. The setting range is from (Rated output voltage – 5V) to  (Rated output voltage - 11V). “Rated output voltage – 5V” is default setting. H: High voltage point for ECO mode. The setting range is from (Rated output voltage + 5V) to ...
  • Page 30 restores, the UPS will return to line mode. Disable: After “Disable” is set, once UPS shutdown occurs and the utility restores, the UPS will  not automatically turn on. Shutdown Delay: UPS will shut down in setting minutes. The countdown will start after confirming ...
  • Page 31 SYSTEM PARAMETER Page 2 SYSTEM PARAMETER Page 3 Model Name: Set the UPS model name.  Serial Number: Set the serial number.  Manufacturer: Set the UPS manufacturer.  Charge Current:  One piece of charger: There are twelve options: 1A, 2A, 3A, 4A, 5A, 6A, 7A, 8A, 9A, 10A, 11A, ...
  • Page 32 INSTALL INSTALL Page  System Install Date: Set the date of UPS installation.  Battery Install Date: Set the date of Battery installation.  Date/Time: Set the date and time. The format is YYYY-MM-DD HH:MM:SS. The calendar day will be automatically changed when the year, month and date are set.
  • Page 33 0.1% no matter it’s pressing up or down key . Press “up” key to increase 0.1% and press “down” key to decrease 0.1%. Press “OK” key to confirm the modification. VOLTAGE CALIBRATE Page3  Line VOLT: Line voltage calibration. Click value columns and it will pop up .
  • Page 34 is 0.1% no matter it’s pressing up or down key . Press “up” key to increase 0.1% and press “down” key to decrease 0.1%. Press “OK” key to confirm the modification. VOLTAGE CALIBRATE Page6  Bypass VOLT: Bypass voltage calibration. Click value columns and it will pop up .
  • Page 35 INITIAL INITIAL menu Page1 INITIAL  Datalog Page DATA LOG: After clicking “DATA LOG”, it will pop up a message board as shown in above screen. Touch  “YES” to clear the DATALOG page. Touch “No” to cancel this operation. Touch “ ”...
  • Page 36 INITIAL CALI Page CALIBRATE: After clicking “CALI”, it will pop up a message board as shown in above screen. Touch  “YES” to restore default calibration value. Touch “No” to cancel this operation. Touch “ ” to return to INITIAL menu page. INITIAL ...
  • Page 37 ELECTRIC Electric Page 1 Output VOL: Select the output rated voltage.  When UPS is HV system, there are four options, 208V, 220V, 230V and 240V.  When UPS is LV system, there are two options, 120V and 127V.  Output FRE: Select output rated frequency.
  • Page 38 setting range is 96V ~ 110V when the UPS is LV system. H: High voltage point for bypass. The setting range is 231V ~ 264V when the UPS is HV system.  The setting range is 139V ~ 146V when the UPS is LV system. Bypass FRE Range: Set the bypass frequency range.
  • Page 39 BATTERY Battery setting page1 Battery setting page2 Battery Warning Voltage:  HIGH: High battery warning voltage. The setting range is 14.0V ~ 15.0V. 14.4V is default setting.  LOW: Low battery warning voltage. The setting range is 10.1V ~ 14.0V. 11.4V is default setting. ...
  • Page 40 OTHERS OTHERS setting page1 Auto Restart:  Enable: After “Enable” is set, once UPS shutdown occurs due to low battery and then utility  restores, the UPS will return to line mode. Disable: After “Disable” is set, once UPS shutdown occurs and the utility restores, the UPS will ...
  • Page 41 SELFTEST This function is only effective when UPS type setting is “HV”. Therefore, please disconnect all loads and utility first before executing this function. Connect Bypass input L1, L2, L3 to Main input L1, L2, L3 respectively. Then, please change UPS type to “HV”. For the detailed operation, please check “System Parameter”...
  • Page 42 Basic Information Page 2 Basic Information MCU Version: MCU version.  DSP Version: DSP version.  LCD Version: DSP version.  Serial NO.: The serial number of UPS.  Rated Information Page1 Rated Information Output Voltage: It shows output rated voltage. ...
  • Page 43 ECO Mode: Enable/disable ECO function.  Parameter Information Page 1 Parameter Information Line Voltage Range: The acceptable line input voltage range.  Line FRE Range: The acceptable line input frequency range.  Bypass Voltage Range: The acceptable input voltage range for bypass mode. ...
  • Page 44 Shutdown Delay: set time to delay ups shutdown.  Restore Delay: UPS will automatically restart in setting minutes after the UPS shuts down.  Battery Numbers: It shows battery number.  3-2-6. Data Log screen Touch the icon to enter date log page. Data log is used to record the warning and fault information of the UPS.
  • Page 45: Audible Alarm

    3-3. Audible Alarm Description Buzzer status Muted UPS status Bypass mode Beeping once every 2 minutes Battery mode Beeping once every 4 seconds Fault mode Beeping continuously Warning Overload Beeping twice every second Others Beeping once every second Fault Beeping continuously 3-4.
  • Page 46 4. Charge the batteries 1) After the UPS is connected to the mains and turned on in AC mode, the charger will charge the batteries automatically except in battery mode, during battery self-test, overload or when battery voltage is high. 2) It’s recommended to charge batteries for at least 10 hours before operation.
  • Page 47 11. Operation in Fault mode 1) When the buzzer beeps continuously, it means that there is a fatal error with the UPS. Users can get the fault code from “DATA LOG” menu. Please refer to the Chapter 4 for details. 2) Please check the loads, wiring, ventilation, mains, battery and so on after the fault occurs.
  • Page 48 4) Enter the command“^S006SOP31” to set the UPS to 31 model. UPS will return “^D006ACK” when it accepts. If you want to set the UPS to 33 model, the command is “^S006SOP33”. Note: This parameter setting is not effected immediately. The setting will be saved only when UPS shut down normally with battery connected.
  • Page 49 31 Schematic diagram for the connection of short circuit sheet copper 33 Schematic diagram for the connection of short circuit sheet copper Second method 1) Press "SETTING" in bypass mode or standby mode. 2) Enter password...
  • Page 50: Parallel Operation

    3) Press "SYS PARSMETER" then go to page 2. Select "Output Settings" and change "3-3" to "3-1". NOTE: The parameter settings will be saved only when UPS shuts down normally with battery connected. 3-5. Parallel Operation 1. Parallel system initial startup Please make sure that all of the running UPSs are parallel models and have the same configuration.
  • Page 51 2. Add new units into the parallel system 1) You can not add new unit into the parallel system when whole system is running. You must cut off the load and shutdown the system. 2) Make sure all of the UPS are the parallel models, and follow the wiring reference in section 2-4. 3) Install the new parallel system as per section 3-5.
  • Page 52: Fault Code

    3-6. Fault Code Fault code Fault event Icon Fault code Fault event Icon Bus start failure None Over temperature None Bus over None DSP communication failure None Bus under None Overload None Bus unbalance None Incorrect UPS setting None Converter over current None MCU communication failure None...
  • Page 53: 3-7.Warning Code

    3-7.Warning Code Warning code Warning event Warning code Warning event Bypass situations are different in Battery unconnected parallel system Locked in bypass after overload 3 IP Neutral loss times in 30 minutes IP phase abnormal Converter current unbalanced Bypass phase abnormal Cover of maintain switch is open Over charge Utility extremely unbalanced...
  • Page 54: Trouble Shooting

    4. Trouble Shooting If the UPS system does not operate correctly, please solve the problem by using the table below. Symptom Possible cause Remedy No indication and alarm in the front The AC input power is not Check if input cable firmly display panel even though the mains is connected well.
  • Page 55: Storage And Maintenance

    5. Storage and Maintenance 5-1. Storage Before storing, charge the UPS at least 7 hours. Store the UPS covered and upright in a cool, dry location. During storage, recharge the battery in accordance with the following table: Storage Temperature Recharge Frequency Charging Duration -25°C - 40°C Every 3 months...
  • Page 56: Specifications

    6. Specifications 400V MODEL 10KL 15KL 20KL 30KL 40KL CAPACITY* 10KVA/10KW 15KVA/15KW 20KVA/20KW 30KVA/30KW 40KVA/40KW INPUT Low Line Loss 110 VAC(Ph-N) ± 3 % at 50% Load; 176 VAC(Ph-N) ± 3 % at 100% Load Voltage Low Line Comeback Low Line Loss Voltage + 10V Range High Line Loss 300 VAC(L-N) ±...
  • Page 57 208V MODEL 7.5KL 10KL 15KL 20KL CAPACITY* 5KVA/5KW 7.5KVA/7.5KW 10KVA/10KW 15KVA/15KW 20KVA/20KW INPUT 70 VAC(Ph-N) ± 3 % at 50% Load Low Line Loss 88 VAC(Ph-N) ± 3 % at 100% Load Low Line Comeback Low Line Loss Voltage + 5V Voltage Range 156 VAC(L-N) ±...
  • Page 59 AGKK15090 01/2024...