Programming (continued)
WIRING
DEVICE
TYPE
3-Button
Remote Control
Programmed as
OPEN/CLOSE/
STOP
Single Button
Remote Control
Programmed
as SBC
C2 (continued)
Single Button
Wall Controller
(Wired)
myQ
Smart
®
Facility Access
ACTION
STATE
Operator at OPEN limit
Operator at CLOSE limit
Door opening
OPEN button
is pressed
Door closing
momentarily
Door at Open Mid-Stop
Door stopped during open or
close cycle
Operator at OPEN limit
Operator at CLOSE limit
Door opening
CLOSE button
is pressed
Door closing
momentarily
Door at Open Mid-Stop
Door stopped during open or
close cycle
Operator at OPEN limit
Operator at CLOSE limit
Door opening
STOP button
is pressed
Door closing
momentarily
Door at Open Mid-Stop
Door stopped during open or
close cycle
Operator at OPEN limit
Operator at CLOSE limit
Door opening
Button is
Door closing
pressed
Door at Open Mid-Stop
Door stopped during open cycle
Door stopped during close cycle
Operator at OPEN limit
Operator at CLOSE limit
Door opening
Button is
Door closing
pressed
Door at Open Mid-Stop
Door stopped during open cycle
Door stopped during close cycle
Button is held
(constant
Door Opening
pressure)
Operator at OPEN limit
Operator at CLOSE limit
Door opening
Open is pressed
Door closing
Door at Open Mid-Stop
Door stopped during open or
close cycle
Operator at OPEN limit
Operator at CLOSE limit
Door opening
Close is pressed
Door closing
Door at Open Mid-Stop
Door stopped during open or
close cycle
RESPONSE
No change in state
Door opens to the OPEN limit or Mid-Stop
No change in state
Door will auto reverse to OPEN limit or Mid-Stop
Door opens to the OPEN limit
Door opens to the OPEN limit or Mid-Stop
No change in state
No change in state
No change in state
No change in state
No change in state
No change in state
No change in state
No change in state
Door stops
Door stops
No change in state
No change in state
No change in state
Door opens to the OPEN limit or Mid-Stop
Door stops
Door will auto reverse to OPEN limit or Mid-Stop
Door opens to the OPEN limit
No change in state
Door opens to the OPEN limit or Mid-Stop
Door closes and stops when button is released
Door opens to the OPEN limit or Mid-Stop
Door stops
Door will auto reverse to OPEN limit or Mid-Stop
Door opens to the OPEN limit
Door closes and stops when button is released
Door opens to the OPEN limit or Mid-Stop
No change in state or Mid-Stop
No change in state
Door opens to the OPEN limit or Mid-Stop
No change in state
Door will auto reverse to OPEN limit or Mid-Stop
Door opens to the OPEN limit
Door opens to the OPEN limit or Mid-Stop
No change in state
No change in state
No change in state
No change in state
No change in state
No change in state