Chamberlain JDC Manual page 39

Industrial dc operators
Table of Contents

Advertisement

Programming (continued)
WIRING
DEVICE
TYPE
T -
Momentary
contact to
open, close,
and stop, with
open override
and Timer-To-
Front panel
Close (TTC).
buttons
Every device
(membrane)
that causes the
and 3-Button
door to open,
Wall
except any
Controller
sensing edge
input device,
activates the
TTC. Auxiliary
controls can be
connected to
open input to
activate the TTC.
If the TTC has
been activated,
the open button
and radio control
can recycle
the timer. The
stop button will
deactivate the
timer until the
next command
input. The TTC
will function
from the Open
limit stop and
Open Mid-Stop
available with
this mode type.
Compatible
3-Button
with 3-Button
Remote
Station, 1-Button
Control
Station and 1
Programmed
and 3-Button
as OPEN/
Remote Control.
CLOSE/
Close Mid-Stop
STOP
is available but
not shown in
table.
Monitored
Entrapment
Protection
(LMEP) Device
required.
Single Button
Remote
Control
Programmed
as SBC
ACTION
STATE
Operator at OPEN limit
Operator at CLOSE limit
Door opening
OPEN
button is
Door closing
pressed
momentarily
Door at Open Mid-Stop
Door stopped during open or close cycle
Operator at OPEN limit
Operator at CLOSE limit
CLOSE
Door opening
button is
pressed
Door closing
momentarily
Door at Open Mid-Stop
Door stopped during open or close cycle Door closes to the CLOSE limit
Operator at OPEN limit
Operator at CLOSE limit
STOP button
Door opening
is pressed
Door closing
momentarily
Door at Open Mid-Stop
Door stopped during open or close cycle No change in state
Operator at OPEN limit
Operator at CLOSE limit
OPEN
Door opening
button
is held
Door closing
(constant
pressure)
Door at Open Mid-Stop
Door stopped during open or close cycle
Operator at OPEN limit
CLOSE
Operator at CLOSE limit
button
Door opening
is held
Door closing
(constant
Door at Open Mid-Stop
pressure)
Door stopped during open or close cycle Door closes to the CLOSE limit
Operator at OPEN limit
Operator at CLOSE limit
OPEN
Door opening
button is
pressed
Door closing
momentarily
Door at Open Mid-Stop
Door stopped during open or close cycle
Operator at OPEN limit
Operator at CLOSE limit
CLOSE
Door opening
button is
pressed
Door closing
momentarily
Door at Open Mid-Stop
Door stopped during open or close cycle Door closes to the CLOSE limit
Operator at OPEN limit
Operator at CLOSE limit
STOP button
Door opening
is pressed
Door closing
momentarily
Door at Open Mid-Stop
Door stopped during open or close cycle No change in state
Operator at OPEN limit
Operator at CLOSE limit
Door opening
Button is
Door closing
pressed
Door at Open Mid-Stop
Door stopped during the open cycle
Door stopped during the close cycle
RESPONSE
No change in state (Recycle timer)
Door opens to the OPEN limit or Mid-Stop (and
activates TTC)
No change in state
Door will auto reverse to OPEN limit or Mid-Stop
(and activates TTC)
Door opens to the OPEN limit (and activates
TTC)
Door opens to the OPEN limit or Mid-Stop (and
activates TTC)
Door closes to the CLOSE limit
No change in state
No change in state
No change in state
Door closes to the CLOSE limit
No change in state (Deactivate timer)
No change in state
Door stops
Door stops
No change in state (Deactivate timer)
No change in state (Recycle & hold timer)
Door opens to the OPEN limit (bypasses Mid-
Stop) and activates TTC
No change in state (bypasses Mid-Stop)
Door will auto reverse to OPEN limit (bypasses
Mid-Stop) and activates TTC
Door opens to the OPEN limit and activates TTC
Door opens to the OPEN limit (bypasses Mid-
Stop) and activates TTC
Door closes to the CLOSE limit
No change in state
No change in state
No change in state
Door closes to the CLOSE limit
No change in state (Recycle timer)
Door opens to the OPEN limit or Mid-Stop and
activates TTC
No change in state
Door will auto reverse to OPEN limit or Mid-Stop
and activates TTC
Door opens to the OPEN limit and activates TTC
Door opens to the OPEN limit or Mid-Stop and
activates TTC
Door closes to the CLOSE limit
No change in state
No change in state
No change in state
Door closes to the CLOSE limit
No change in state (Deactivate timer)
No change in state
Door stops
Door stops
No change in state (Deactivate timer)
Door closes to the CLOSE limit
Door opens to the OPEN limit or Mid-Stop and
activates TTC
Door stops
Door will auto reverse to OPEN limit or Mid-Stop
and activates TTC
Door opens to the OPEN limit and activates TTC
Door closes to the CLOSE limit
Door opens to the OPEN limit or Mid-Stop and
activates TTC
39

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents