Chamberlain MEGA SWING Owner's Service Manual

Chamberlain MEGA SWING Owner's Service Manual

1/2 hp commercial duty swing gate operator

Advertisement

The Chamberlain Group, Inc.
845 Larch Avenue
Elmhurst, Illinois 60126-1196
www.liftmaster.com
Model MSWDCBB
(MEGA SWING UL)
1/2 HP COMMERCIAL DUTY SWING GATE OPERATOR
OWNER'S SERVICE MANUAL
THIS UNIT IS A CLASS 1, 2, 3, OR 4 SWING GATE OPERATOR FOR USE IN SWING GATE APPLICATIONS

Advertisement

Table of Contents
loading

Summary of Contents for Chamberlain MEGA SWING

  • Page 1 845 Larch Avenue Elmhurst, Illinois 60126-1196 www.liftmaster.com Model MSWDCBB (MEGA SWING UL) 1/2 HP COMMERCIAL DUTY SWING GATE OPERATOR OWNER’S SERVICE MANUAL THIS UNIT IS A CLASS 1, 2, 3, OR 4 SWING GATE OPERATOR FOR USE IN SWING GATE APPLICATIONS...
  • Page 2: Table Of Contents

    T A B L E O F C O N T E N T S I N T R O D U C T I O N REPAIR PARTS INTRODUCTION Carton Inventory........3 ACCESSORIES Manual Release .
  • Page 3: Introduction

    I N T R O D U C T I O N MANUAL RELEASE CARTON INVENTORY To operate gate manually, REMOVE top plastic cover on top of arm. Locate RED release handle. Before beginning your installation check that all components were provided and received undamaged.
  • Page 4: Ul325 Model Classifications

    UL325 ENTRAPMENT PROTECTION REQUIREMENTS SAFETY ACCESSORY SELECTION GATE OPERATOR ENTRAPMENT PROTECTION All UL325 compliant LiftMaster gate operators will accept external entrapment protection devices to protect people from motorized UL325 Slide Gate Operator Swing &...
  • Page 5: Safety Installation Information

    SAFETY INSTALLATION INFORMATION 1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one component. Each gate system is specifically designed for an individual application. 2. Gate operating system designers, installers and users must take into account the possible hazards associated with each individual application.
  • Page 6: Safety Precautions For Swing And Ornamental "Grill Type Gates

    SAFETY PRECAUTIONS FOR SWING AND ORNAMENTAL "GRILL TYPE GATES" WARNING WARNING WARNING To prevent SERIOUS INJURY or DEATH from a moving gate: CAUTION WARNING • Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate. •...
  • Page 7: Recommended Photo Cell Layout For Secondary Entrapment Protection

    Please use all safety devices on your installation to achieve the safest operation. (This is a view from above gate.) Photo Cell (Do Not Allow Any Pinching At Hinge) Safety Beam (Note-2 & 3) Reflector or MEGA SWING UL Transmitter Gate Leaf Wall or Fence Closes This Direction...
  • Page 8: Operator Overview

    OPERATOR OVERVIEW The LiftMaster model MEGA SWING UL swing gate operator is unique in the industry. Setting the MEGA SWING UL apart are many features that make it the front runner in its class. With standard features like: • Built in battery run - inherent 24 Vdc backup power with regulated 24 Vdc for accessories.
  • Page 9: Installation

    3/8" thick base as well Gate Plate as washers for any leveling. See drawing on page 3A. CONDUITS The Mega Swing UL is equipped with 1/2 and 3/4 knockout in the Pad 24" Deep Elbow 24" Wide back of the accessory cabinet.
  • Page 10: Wiring And Hookup

    WARNING W I R I N G A N D H O O K U P WARNING WARNING To reduce the risk of SEVERE INJURY or DEATH: • DO NOT install ANY wiring or attempt to run the operator without consulting the wiring diagram. We recommend that •...
  • Page 11: Input Commands Connections

    INPUT COMMANDS CONNECTIONS Terminal 5, Safety - Safety edge(s) and safety loop input. This function will make the gate reverse and go back to the open (Use common and normally open contacts from devices position if it was closing. Input is for all NORMALLY OPEN connected to these inputs) contact safety devices.
  • Page 12: Accessory Connections

    ACCESSORY CONNECTIONS These terminals will provide battery backed power to 24 Vdc devices and are located at the bottom of the electronic control board at J4 terminals 1 and 2. Terminal 1 is 24 Vdc (+) and number 2 is 0 Vdc (-). Peripheral CLASS 2 low voltage devices that require 24 Vdc power maybe connected here (500 ma.
  • Page 13: T I M E R S A N D M O D E S E L E C T I O N S S 1 & S 2

    IRD1 BRAKE CLOSE U1Ø CLOSE TIMER - SWITCH PACK S2 (1-5) On the MEGA SWING UL the switches 1-5 on S2 are for the D2Ø 1A DC R2Ø WARNING FOR closing timer delay. If S2-7 is on, the gate will auto close by timer.
  • Page 14: Adjustments

    A D J U S T M E N T S RIGHT OR LEFT HAND OPERATION RIGHT HAND OPERATION UNIT SHIPS AS RIGHT-HAND OF FUSE AUX. LIMITS Method 1: No longer used as of August 16, 2003. The S1-7 Green (Open &...
  • Page 15: Install The Receiver

    I N S T A L L T H E R E C E I V E R WARNING NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of WARNING WARNING this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery.
  • Page 16: Maintenance

    (Set with R63, shown on the • Disconnect ac power at the fuse box. Control Board Layout page). • Disconnect dc power at the battery connection. • Replace batteries with LiftMaster P/N MBAT batteries. Replace in pairs. BATTERY DISPOSAL BATTERY MAINTENANCE / TESTING Replaced batteries must be treated as a hazardous waste and The batteries are maintenance free.
  • Page 17: Troubleshooting

    T R O U B L E S H O O T I N G BATTERY CHECKOUT WARNING WARNING WARNING When the batteries become weak the gate will begin to run noticeably slower. (NOTE: Batteries should only be checked when To prevent possible SERIOUS INJURY or DEATH from you are sure they have had adequate time to fully charge.) Turn electrocution or fire, BEFORE proceeding:...
  • Page 18: Suggested Loop Sensor Locations

    Terminal #8 for shadow loop. ENTRY WITH ACCESS CONTROL DEVICE Gate will open when activated by an access control device. When Mega Swing UL timer expires (if used), gate will close (Figure 2). Terminal #5 is safety input. Terminals #1, 2, and 3 are open inputs.
  • Page 19: Control Board Layout

    C O N T R O L B O A R D L A Y O U T Open Gate Inputs - Reader, Push Button Aux Open / Reset (Pulse Open/Close) Safety Loop Input Close Gate Input - Close Loop Back Away - Free Exit Loop Shadow Loop Commons - 0 Vdc...
  • Page 20 R E P A I R P A R T S FRONT VIEW REAR VIEW SIDE VIEW Gear Box Frame Arm Ends Nylon Washer Nylon Washer Mounting Bolt/Nut Set Screws Extension Tube Arm Ends Elbow Gate Plate Bolt/Nut Bolt/Nut Gate Plate INDIVIDUAL PARTS INDIVIDUAL PARTS ITEM PART #...
  • Page 21: Safety Accessories For Secondary Entrapment Protection

    A C C E S S O R I E S 371LM ® Wiring Harness: For the A24. Security✚ Single Button Remote Control : Includes visor clip. UN201 Heater Option: 500 watt with thermostat, use for 32° and below temperatures (mounting bracket included).
  • Page 22 L I M I T E D W A R R A N T Y LIFTMASTER 2 YEAR LIMITED WARRANTY 10 YEAR CORROSION/PERFORATION LIMITED WARRANTY ON COVER AND CHASSIS The Chamberlain Group, Inc. (“Seller”) warrants to the first purchaser of this product, for the structure in which this product is...
  • Page 23 OUR LARGE SERVICE ORGANIZATION SPANS AMERICA INSTALLATION AND SERVICE INFORMATION IS AS NEAR AS YOUR TELEPHONE. SIMPLY DIAL OUR TOLL FREE NUMBER: 1-800-528-2806 www.liftmaster.com WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • PART NAME • MODEL NUMBER ADDRESS ORDERS TO: THE CHAMBERLAIN GROUP, INC.
  • Page 24 INSTALLATION CHECK OFF LIST This Swing Gate operator is installed for use in a Class _____ installation. Each item on this installation check off list should be verified by the installer. _____ Two warning signs securely installed on each side of gate panel (required). _____ 1 or 2 safety photo beams installed, one across each side of gate opening (required).

Table of Contents