11. Maintenance overview

The following maintenance measures must be carried out on a regular basis:
Clean and oil the guide rail and rack.
Oil the guides.
Remove built-up melt parts from the cutting strips.
Empty and clean the water container.
Clean and oil the Z-axis spindle.
Lubricate the guide blocks.

12. Problem detection

12.1 The machine does not switch on

Check the power cable of the control box.
Check whether the control box switch is turned on.
Check the fuse at the power input of the control box.

12.2 Controls not working

Check whether the emergency stop is activated.
When the ''soft-limits'' are enabled, they may have been reached or the 0/reference point may not have
been set correctly.
Check whether the ''FEED RATE'' is not set too low.

12.3 Plasma cutter does not cut through the material

If the plasma cutter does not deliver good cutting quality, this may be due to the following causes:
Check whether the negative connection of the plasma cutter makes good contact with the workpiece to be
cut.
The material is too thick to cut through.
The distance between the workpiece and the plasma cutter head is too large.
The cutting speed is too high.
The plasma cutter amperes are not set correctly.
The plasma nozzle is worn or incorrect.
For more troubleshooting, visit:
https://pritec-automation.com/pages/problem-solutions

13. Warranty

The warranty comes into effect on the date stated on the purchase invoice and is valid for 12 months.
The warranty is not transferable without written permission from your supplier.
Without a purchase invoice, no warranty claim can be made.