Sdi-12 Output Definitions - FlowLine EchoBeam LR80 Series Manual

Hide thumbs Also See for EchoBeam LR80 Series:
Table of Contents

Advertisement

Appendix

SDI-12 OUTPUT DEFINITIONS

Serial Port Setting
SDI 1200 baud rate 1 start, 7 data, 1 parity even, 1 stop.
Supports SDI 1.4
Supported Commands
No.
Name
Break
Acknowledge
1
Active
Send
2
Identification
3
Address Query
Change
4
Address
Start
5
Measurement
Start
6
Concurrent
Measurement
7
Send Data
Continuous
8
Measurements
Additional
9
Measurements
Additional
10
Concurrent
Measurements
Start
11
Verification
Start
Measurement
12
and Request
CRC
Additional
Measurement
13
and Request
CRC
MN310255 Rev 10
Command
Response
Continuous spacing
for at least 12
None
milliseconds
a!
a<CR><LF>
a14FLowLinemmmmmmvvvxxx,CR><LF>
aI!
Manufacturer serial number and other information
?!
a<CR><LF>
aAb!
b<CR><LF>
aM!
a0004<CR><LF> Response: 4
aC!
a00004<CR><LF> Response: 4
aD0!
a+4 values: height+distance+temperature+error code
a<values><CR><LF>
aD1! ... aD9!
a+4 values: height+distance+temperature+error code
aR0!
aR1! ... aR9!
a<values><CR><LF>
aM1! ... aM9!
a0000<CR><LF>
aC1! ... aC9!
a00000<CR><LF>
aV!
a0004
aMC!
Attn<CR><LF>
aMC*!
Attn<CR><LF>
Section Fifteen
101
|

Advertisement

Table of Contents
loading

Table of Contents