Sign In
Upload
Manuals
Brands
FlowLine Manuals
Transmitter
EchoPro LR31 Series
FlowLine EchoPro LR31 Series Manuals
Manuals and User Guides for FlowLine EchoPro LR31 Series. We have
3
FlowLine EchoPro LR31 Series manuals available for free PDF download: Manual, Quick Start Manual
FlowLine EchoPro LR31 Series Manual (92 pages)
Brand:
FlowLine
| Category:
Transmitter
| Size: 4 MB
Table of Contents
Section One | Introduction
2
Table of Contents
2
Sensor Models
5
Benefits
6
Features
6
Limitations
6
Operating Principle
6
Specifications
7
Intrinsically Safe Control Drawings
12
Labels for Intrinsic Safety
13
Dimensions
14
Safety Precautions
17
Section Two | Getting Started
18
Setup Overview
18
Part Number
20
Section Three | Install Sensor
22
Installation Requirements
22
FCC Conformity
23
LR16 Antenna Preparation
24
Mounting Position
25
Flange Riser Installation
28
Beam Angle
29
Stand Pipe Installation
30
Bypass Installation
31
LR31 Sensor Installation
32
LR98 Display Installation
33
Section Four | Wire Sensor
34
Terminal Wiring
34
HART ® Device Descriptors (DD Files)
35
Standard Vs Multidrop
35
HART ® Wiring
35
LR31 Configuration
36
LR31 Wiring and Description
36
Using Lr98 Display as Hmi for Lr31 Series
37
Wiring to Displays, Controllers & Plcs
38
Section Five | Configuration Using Display
40
Basic Configuration Overview
40
Basic HART Communicator Overview
41
Units of Measurement
42
Sensor Height
42
Fill-Height
43
Maximum Range
43
Dead Band
44
Echo Curve
44
Using the Display
45
Changing Display Values
46
Step 1 - Measure the Tank
47
Step 2 - Set the Units of Measurement
48
Step 3 - Set the Sensor Height (4Ma)
49
Step 4 - Set the Fill-Height (20Ma)
50
Step 5 - Set the Range (Maximum Range)
51
Step 6 - Set the Dead Band
52
Step 7 - Check the Echo Curve
53
Section Six | Process Adjustments
54
Process Adjustments Overview
54
Fast Filling or Emptying of Liquid
55
Liquid Requiring First Echo Adjustment
56
Liquid Surface Is Turbulent or Agitated
57
Foam on the Surface of the Liquid
58
Liquids with Low Dielectric
59
Sensor Installed in a Stand Pipe or Sight Glass
60
Section Seven | Advanced Adjustments
61
Advanced Adjustments Overview
61
4-20Ma Reverse Output
62
Fail-Safe Output
63
Minimum Current Output
64
HART ® Operation Mode
65
Create a New False Echo Curve
66
Update an Existing False Echo Curve
67
Section Eight | Troubleshooting
68
Troubleshooting Overview
68
Measurement Status
69
Peak Values
70
Simulation
71
First Echo Adjustment
72
Echo Curve Zoom
73
False Echo Curve Delete
74
Reset
75
Section Nine
76
Configuration Menu
76
Section Nine | Appendix:
76
Empty Configuration
77
Full Configuration
77
Medium
78
Liquid Medium
78
Solids Medium
79
Low Dielectric Medium
80
Dampen
80
Scaled Units
80
Dead Band
81
Range
81
Display Menu
82
Display Value
82
LCD Contrast
82
Diagnostics Menu
83
Measurement Status
83
Peak Values
83
Echo Curve
84
Simulation
84
Service Menu
85
False Echo
86
Output Settings
86
HART ® Operational Mode
87
Information
88
Factory Settings
89
User Configuration
89
Troubleshooting
90
Language
87
Reset
87
Units of Measurement
87
Section Ten | Warranty, Returns and Limitations
92
Warranty
92
Returns
92
Limitations
92
Advertisement
FlowLine EchoPro LR31 Series Quick Start Manual (25 pages)
Radar Liquid & Solid Level Transmitter
Brand:
FlowLine
| Category:
Transmitter
| Size: 1 MB
Table of Contents
Quick Start
2
Sensor Models
2
Fcc Conformity
3
Using the Display
4
Menu Introduction
4
Basic Configuration Overview
5
Step 1 - Measure the Tank
6
Step 6 - Set the Dead Band
12
Analog Output (4-20 Ma)
18
Hart ® Wiring
21
Warranty
24
FlowLine EchoPro LR31 Series Quick Start Manual (4 pages)
Radar Liquid Level Transmitter
Brand:
FlowLine
| Category:
Transmitter
| Size: 0 MB
Table of Contents
Configure Lr30 or Lr31 to a Pressure Transmitter Range
1
Step 1 – Identify the Span of the Pressure Transmitter
1
Example in Feet
2
Example in Meters
2
Step 2 – Measure the Sensor Height of the Radar Transmitter
2
Step 3 – Determine the Offset Distance
3
Example in Feet
3
Example in Meters
3
Step 4 – Record the Factory Distance Adjust Value
3
Step 5 – Calculate the New Distance Adjust
4
Step 6 – Configure the Radar Transmitter
4
Example in Feet
4
Example in Meters
4
Advertisement
Advertisement
Related Products
FlowLine EchoPulse LR30 Series
FlowLine EchoPulse LR30-0010-10
FlowLine EchoPulse LR15 Series
FlowLine EchoPulse LR20 Series
FlowLine EchoPro LR11 Series
FlowLine EchoPro LR21 Series
FlowLine EchoPulse LR15-0010-30
FlowLine EchoBeam LR85 Series
FlowLine EchoBeam LR83 Series
FlowLine EchoPro LR16 Series
FlowLine Categories
Transmitter
Switch
Measuring Instruments
Controller
Accessories
More FlowLine Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL