5. Controlled roller motor connect properly to terminals 3 and
4 and to N.
6. Take ON the power.
7. Programming to time of upwards/downwards of roller. Pre-
scribed is that programmed time should be longer than 10 sec
from real time of upwards/downwards.
Technical data
power supply
maximum load current (AC-1/AC-3)
power of connected single-phase motor
control
control pulse current for L/N
switch-on time (adjustable)
power indication
programming indication
power consumption
working temperature
signal terminal
supply terminal
dimensions
mounting
ingress protection
The controller uses the strength of the contact relay 8 A
to resistive load. Due to the inductive nature of the char-
ge introduced by the engine shutters should not be char-
ged more than the contact current 1.5 A. Corresponds to
power of motor about 320 W.
triggered by level L or N
2×DY 1.5mm², l=10 cm
in fl ush-mounted box ø60
- 6 -
230 V AC
8 A/1.5 A
0 sec÷10 min.
green LED
green LED
-25÷50°C
4×DY 1mm², l=10 cm
ø55, h= 20 mm
320 W
<1mA
<1 W
IP20