Controller control inputs
local control – a group of push-buttons that controls one rol-
ler blind which are connect to terminals 5 and 6.
↑ – upwards (opening); ↓ – downwards (closing)
Pressing the local control push-button activates the movement
of the roller blind in a selected direction. If the roller blind is
already moving, pressing the local control push-button will stop
the roller blind.
central control – a common group of push-buttons which
are connect to joint 7 and 8 for many controllers (minimum two
controllers) that controls all roller blinds included in the central
control system.
↑↑ – all upwards; ↓↓ – all downwards.
Pressing the central control push-button activates the move-
ment of the roller blinds in a selected direction. If one of the
roller blinds is already moving in the same direction, its move-
ment will be continued. If one of the roller blinds is moving in
the opposite direction, this roller blind will be first stopped and
then its movement will be activated in the direction in accordan-
ce with the command sent to the central input.
The central control enables only activating the move-
ment of the roller blinds in a selected direction. The
roller blind will be stopped after the programmed move-
ment time or when any of the local control push-buttons
is pressed.