Advertisement

Programming time of enclose
1. Press and hold a button proG for time when green LED "U"
start to pulsate.
2. When we again press a button proG (Start). Controller start
count a time which is to signal by pulsate of green LED.
3. Press again a button proG (Stop). Controller remember a co-
unted time. Programmin mode is automaticly closed ( green
LED U shine continually).
If at time 30 sec from start programming mode a count
of time doesn't to start, then controller will out from
programming mode.
Max time for programming 10 min. Test by long time
than 10 min. to cause controller automatically out from
programming mode.
Input to programming mode posible is only when motor
of roller is OFF.
In programming mode a controller doesn't to react for
outward control signal.