Synchronization failed in
Here we have to distinguish between hardware issues (camera and external synchroniza-
tion) and software issues:
1. Check the cabling (hardware issue):
Please make sure that the cables themselves are not damaged.
Take care of using the correct ports:
– OUT1 to OUT3: synchronization of the cameras
– EXT.In: input of the external synchronization
Double-check if no extensions between camera and terminating resistor have
been made.
double-check if the terminating resistor is missing at the end of the signal line.
Splitting of the synchronization line is not allowed.
ARTTRACK
2 & 3 systems (discontinued)
6.2 Synchronization