Huawei SmartLogger3000 Configuration Manual page 20

Hide thumbs Also See for SmartLogger3000:
Table of Contents

Advertisement

SmartLogger3000
Export Limitation Configuration Guide
Figure 3-6
Parameter
Start control
Electric meter
power direction
Issue 04 (2022-10-24)
Parameter Configuration
Value Range
Yes/No
Positive/Reverse
Copyright © Huawei Technologies Co., Ltd.
3 Configuting Export Limitation Feature
Default Value
No
Reverse
Description
Enable/Disable
Export Limitation
feature. Set this
parameter to Yes.
Otherwise, the
export limitation
feature does not
take effect.
Set this parameter
to Positive if the
active power
reading of the
power meter is
positive when the
inverter has no
power output.
Otherwise, set this
parameter to
Reverse.
15

Advertisement

Table of Contents
loading

Table of Contents