Electrostatic Discharge Safety; Laser Safety; Installation Environment Requirements; Ventilation Requirements - QTech QSW-6300 Series Hardware Installation And Reference Manual

Table of Contents

Advertisement

QSW-6300 Series Switches Hardware Installation and Reference Guide
Preparing for Installation
current supports no more than four power supplies. In this case, the eight power supplies
in the system require at least two leakage protectors with 30 mA rated action current
and each leakage protector supports four power supplies. If power supplies in a system
differ in models, the rated leakage action current of each leakage protector divided by
two is greater than the sum of maximum leakage currents of all the power supplies. The
rated leakage non-action current of a leakage protector shall be 50% of the leakage
action current. Take a leakage protector with 30 mA rated leakage action current as an
example. The rated leakage non-action current shall be 15 mA. When the leakage
current is below 15 mA, the protector shall not act. Otherwise, misoperation may easily
occur due to high sensitivity and thus the leakage protector trips, devices are powered
off, and services are interrupted.
To guarantee personal safety, the rated leakage action current of each leakage protector
in the system must be equal to or less than 30 mA (human body safety current is 30
mA). When twice of the total leakage current of the system is greater than 30 mA, the
system must be equipped with two or more leakage protectors.
For the leakage current value of each power supply model, see the power supply model
parameter table in Chapter 1.

2.1.4. Electrostatic Discharge Safety

To ensure electrostatic discharge safety, there are some precautions:
Properly ground the device and floor.
Keep the indoor installation environment clean and dust-free.
Maintain appropriate humidity conditions.

2.1.5. Laser Safety

Among the modules supported by the QSW-6300 series, here are many transceiver modules
that are Class I laser products.
Precaution:
When a fiber transceiver works, ensure that the port has been connected with a fiber or
covered by a dust cap to keep out dust and prevent it from burning your eyes.
Note:
Do not approach or stare at any fiber port under any circumstances, as this may cause permanent
damage to your eyes.

2.2. Installation Environment Requirements

Install the switch indoors to ensure its normal operation and prolonged service life.
The installation site must meet the following requirements.

2.2.1. Ventilation Requirements

QSW-6300 should be placed at least 10 cm away from surrounding walls to ensure normal heat
dissipation. After various cables are connected, bundle the cables or place them in the cable
management bracket to avoid blocking air inlets.

2.2.2. Temperature/Humidity Requirements

To ensure the normal operation and prolonged service life of the QSW-6300 switch, maintain an
appropriate temperature and humidity in the equipment room.
The equipment room with too high or too low temperature and humidity for a long period may
damage the switch.
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qsw-6300-32tQsw-6300-52tQsw-6300-32f

Table of Contents