Pump Overview; Pump Description; Specifications; Pump Performance - Pentair PCD-1000 Installation And User Manual

Stainless steel utility pump
Table of Contents

Advertisement

1

PUMP OVERVIEW

Pump Description

This submersible sump pump is designed for draining
and utility applications. The pump features a stainless
steel casing, suction strainer, impeller and shaft, along
with permanently lubricated ball bearings and automatic
thermal overload protection. Includes a float switch and
a PVC elbow.
Equipped with 15-foot, 18/3 grounding type power
cord.
Optional tethered float switch for automatic operation
Clog-resistant cast stainless steel impeller, ceramic
shaft facings, and oil chamber for efficient seal
lubrication.
115V, 60 Hz, single phase permanent split capacitor
motor

Pump Performance

Model
HP
PCD-1000
3/4
Model
PCD-1000

General Information

Electrically powered sump pumps can provide many
years of trouble-free service when correctly installed,
maintained, and used. However, unusual circumstanc-
es may prevent your pump from functioning normally,
such as:
Interruption of power to the pump
Dirt/debris in the sump
Flooding that exceeds the pump's capacity
Electrical or mechanical failure in the pump.
PCD-1000 SUBMERSIBLE PUMP Installation and User's Guide
Motor Full
Load
(Amps)
RPM
6.4
3450
GPM of Water @ Total Feet of Head
HP
5'
3/4
45.5

Specifications

The pump is designed for 115 VAC, 60 Hz operation
and requires a minimum 15 amp dedicated circuit.
Both pump and switch are supplied with three wire
cord sets with grounding-type plugs.
Power supply required .................. 115VAC, 60 Hz
Motor duty .......................................... Continuous*
Dedicated Circuit Requirement (min) ...... 15 Amps
Pump Discharge ...........................1-1⁄4" Male NPT
Discharge Adapter:........1-1⁄4" Female NPT Elbow
Passes solids up to: ........................................ 3/4"
*Note: For continuous operation, water depth
must be at least 2" (5 cm).
Minimum
Liquid
Circuit Req.
Temperature
(Amps)
Range
32/130° F
15
0/54° C
10'
15'
34.0
21.5
To prevent possible water damage due to flooding, con-
sult your retailer about a secondary AC sump pump, a
DC backup sump pump, and/or a high water alarm.
See the "Troubleshooting" in section 4 of this manual for
information about common sump pump problems and
corrective action. Note: No repair parts are available for
this pump.
Switch
Pumps
Setting
Down
On
Off
6"
12"
15.2
1-3/8" 3.5
30 cm
cm
Shut off
20'
12.0
26.2'
To
cm