Solids handling

Advertisement

Quick Links

DRY PIT
4VCDP
SOLIDS HANDLING
DRY PIT PUMPS
INSTALLATION AND SERVICE MANUAL
NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible
party who maintains the system.
Part # 05625-556-1 | © 2013 Pentair Ltd. | 11/18/13

Advertisement

Table of Contents
loading

Summary of Contents for Pentair Myers DRY PIT 4VCDP

  • Page 1 INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system. Part # 05625-556-1 | © 2013 Pentair Ltd. | 11/18/13...
  • Page 2: California Proposition 65 Warning

    GENERAL Wet Well Level Control: Sump level is controlled by Myers switch controls. The float is held in position Shipping: When unpacking unit, check for concealed in the sump by a weight attached to the power cord damage. CLAIM FOR DAMAGE MUST BE MADE AT above the float.
  • Page 3 factory water testing, so it must be broken loose with connections are tightened. The use of expansion a small bar or screwdriver in the edge of the vanes. joints or vibration pads does not preclude the need to The impeller must turn freely. properly support the piping.
  • Page 4 Discharge-Outlet Piping: The discharge piping for More distance between turn-on and turn-off short runs can be of the same size as the discharge of controls can be used, but sewage may become the pump. It is recommended that longer runs be 1 to septic, and excessive solids may collect for the 2 sizes larger depending on the length.
  • Page 5: Pump Operation

    PUMP OPERATION Servicing Instructions: Starting System: IMPORTANT: Read all instructions prior to 1. Turn H-O-A switch to Off position and then turn on replacing any parts. main circuit breakers. 2. Open all discharge valves and allow water to rise in WARNING: Before handling these pumps wet well.
  • Page 6: Pump Troubleshooting

    Pump does not deliver proper capacity. 13. Examine all O-rings for nicks before using and replace damaged O-rings with new ones. 1. Discharge gate valve may be partially closed or 14. Use Loctite on socket head impeller locking partially clogged. ®...
  • Page 7 THIS PAGE INTENTIONALLY LEFT BLANK...
  • Page 8: Standard Limited Warranty

    STANDARD LIMITED WARRANTY Myers warrants its products against defects in material and workmanship for a period of 12 months from the date ® of shipment from Myers or 18 months from the manufacturing date, whichever occurs first - provided that such products are used in compliance with the requirements of the Myers catalog and technical manuals for use in pumping raw sewage, municipal wastewater or similar, abrasive free non-corrosive liquids.