Pentair PENBERTHY GL Installation, Operation And Maintenance Instructions

Pentair PENBERTHY GL Installation, Operation And Maintenance Instructions

Jet pumps

Advertisement

Quick Links

NORTHEAST CONTROLS INCORPORATED
PENBERTHY
Jet
Pumps
Models GL, GH - Gas Operated
Installation, Operation and Maintenance Instructions
NORTHEAST CONTROLS INCORPORATED
TEL: 201-419-6111 ext. 23 for Venturi Group
®
TEL: 201-419-6111 ext. 23 for Venturi Group
www.jrgjt.com
Section: 1000
I.O.M.: 1951
Issued: 05/15
Replaces: 12/04
sales@jrgjt.com

Advertisement

Table of Contents
loading

Summary of Contents for Pentair PENBERTHY GL

  • Page 1 NORTHEAST CONTROLS INCORPORATED TEL: 201-419-6111 ext. 23 for Venturi Group www.jrgjt.com Section: 1000 I.O.M.: 1951 Issued: 05/15 Replaces: 12/04 PENBERTHY ® Pumps Models GL, GH - Gas Operated Installation, Operation and Maintenance Instructions NORTHEAST CONTROLS INCORPORATED TEL: 201-419-6111 ext. 23 for Venturi Group sales@jrgjt.com...
  • Page 2: Table Of Contents

    NORTHEAST CONTROLS INCORPORATED TEL: 201-419-6111 ext. 23 for Venturi Group www.jrgjt.com TABLE OF CONTENTS Product Warranty 1.0 About the Manual . 2.0 Introduction 2.1 Features and Specifications. 2.2 Design Ratings at Max. and Min. Operating Temperatures 2.3 Application Data 3.0 Inspection and Performance Confirmation . 3.1 Receiving Inspection 3.2 User's Rating Inspection.
  • Page 3: Product Warranty

    PENBERTHY PRODUCT WARRANTY Pentair Valves & Controls Black Mountain warrants its Penberthy products as designed and manufactured by PV&C Black Mountain to be free of defects in the material and workmanship for a period of one year after the date of installation or eighteen months after the date of manufacture, whichever is earliest.
  • Page 4: About The Manual

    NORTHEAST CONTROLS INCORPORATED TEL: 201-419-6111 ext. 23 for Venturi Group www.jrgjt.com INSTALLATION, OPERATION and MAINTENANCE MANUAL FOR PENBERTHY MODELS GL & GH JET PUMPS 1.0 About the Manual This manual has been prepared as an aid and guide for personnel involved in installation or maintenance.
  • Page 5: Inspection And Performance Confirmation

    NORTHEAST CONTROLS INCORPORATED TEL: 201-419-6111 ext. 23 for Venturi Group www.jrgjt.com WARNING Under no circumstances should these design ratings or application data be exceeded. Exceeding design ratings or application data may cause bursting of steam jet pump, discharge of live steam, objectionable noise and vibration, loosening of joints, leaks and suction flow reversal, resulting in severe physical injury or property damage.
  • Page 6: Effect Of Related Piping And Precautions

    NORTHEAST CONTROLS INCORPORATED TEL: 201-419-6111 ext. 23 for Venturi Group www.jrgjt.com 4.1 Effect of Related Piping and Precautions 1. Penberthy gas operated jet pump models GL and GH may be installed and operated in any position. Jet pumps should be installed with pipe and fittings which provide minimum resistance to fluid flow.
  • Page 7: Operation

    NORTHEAST CONTROLS INCORPORATED TEL: 201-419-6111 ext. 23 for Venturi Group www.jrgjt.com Figure 1 Typical Installation Figure 2 Schematic Gas Operated Typical Installation Pumping Gases Schematic Steam Operated Pumping Water 5.0 Operation 5.1 Pre-Operational Check 1. Assure that all installation procedures have been completed. 2.
  • Page 8: Preventative Maintenance

    NORTHEAST CONTROLS INCORPORATED TEL: 201-419-6111 ext. 23 for Venturi Group www.jrgjt.com 6.1 Preventative Maintenance The following items should be regularly monitored for purposes of maintenance: 1. Jet pump units for corrosion or debris build up 2. Piping and fittings for corrosion or debris build up 3.
  • Page 9: Telephone Assistance

    NORTHEAST CONTROLS INCORPORATED TEL: 201-419-6111 ext. 23 for Venturi Group www.jrgjt.com 9.0 Telephone Assistance If you are having difficulty with your Jet Pump, contact your local Penberthy distributor. So that we may assist you more effectively, please have as much of the following information available as possible when you call: Model # Name of the company from whom you purchased the Jet Pump...
  • Page 10: Exploded Parts Drawing

    NORTHEAST CONTROLS INCORPORATED TEL: 201-419-6111 ext. 23 for Venturi Group www.jrgjt.com 10.0 Exploded Parts Drawing Figure 3 NORTHEAST CONTROLS INCORPORATED TEL: 201-419-6111 ext. 23 for Venturi Group sales@jrgjt.com...
  • Page 11 NORTHEAST CONTROLS INCORPORATED TEL: 201-419-6111 ext. 23 for Venturi Group www.jrgjt.com NOTES NORTHEAST CONTROLS INCORPORATED TEL: 201-419-6111 ext. 23 for Venturi Group sales@jrgjt.com...
  • Page 12 Pentair Valves & Controls 953 Old U.S. Highway 70, Black Mountain, North Carolina 28711 Printed in USA Part No. 14868-009 © 2015 Pentair Valves & Controls, Black Mountain, All Rights Reserved NORTHEAST CONTROLS INCORPORATED TEL: 201-419-6111 ext. 23 for Venturi Group sales@jrgjt.com...