  • Page 1 USER‘S MANUAL SIKU RV 50 W Pro WiFi V2 SIKU RV 30 DW Pro Duo WiFi V2 Single-room reversible energy recovery ventilator siku.at...
  • Page 2 SIKU RV 30/50 (D)W Pro WiFi V2 its products at any time in order to incorporate the unit and all its modifications. latest technological developments. No part of this...
  • Page 3 RV 30/50 (D)W Pro WiFi V2 SIKU • Do not change the power cable length at your own discretion. Do not bend the • Do not lay the power cable of the unit in power cable. Avoid damaging the power close proximity to heating equipment.
  • Page 4 DELIVERY SET NUMBER NAME SIKU RV 50 W Pro WiFi V2 SIKU RV 30 DW Pro Duo WiFi V2 1 Pcs 1 Pcs INDOOR UNIT OF THE VENTILATOR 1 Pcs...
  • Page 5 100 (+20) Transmission power, mW (dBm) MODELS L (MM) DHCP SIKU RV 50 W Pro WiFi V2 Network SIKU RV 30 DW Pro Duo WiFi V2 WLAN-security OVERALL DIMENSIONS OF THE INDOOR UNIT, MM RV 50 W PRO WIFI V2...
  • Page 6 UNIT DESIGN AND OPERATING PRINCIPLE The ventilator consists of an indoor unit with a SIKU RV 30 DW Pro Duo WiFi V2 are equipped with a set decorative front panel, a cartridge, an air duct of air flow separators. The design of the and an outer ventilation hood.
  • Page 7 AUTOMATIC SHUTTERS ARE CLOSED AUTOMATIC SHUTTERS ARE OPEN VENTILATOR OPERATION MODES SIKU RV 50 W PRO WIFI V2 SIKU RV 30 DW PRO DUO WIFI V2 one of the ventilator fans operates in Ventilation: the ventilator runs either in extract...
  • Page 8 3 mm The length of the ventilation pipe can be adjusted before or after fixing the ventilation pipe in the wall. In the second case, there must be sufficient access to the outer wall after installing the ventilation pipe. siku.at siku.at...
  • Page 9 RV 30/50 (D)W Pro WiFi V2 SIKU 3. Stick the delivered cardboard master plate on the indoor wall MARKING THE using a mounting tape. The large opening in the master plate must MOUNTING HOLES (MM) be axially aligned with the air duct. For aligning the master plate with respect to the horizon line it is recommended to use a Ø...
  • Page 10 8. Place the front part of the inner element. SIKU RV 50 W PRO WIFI V2 SIKU RV 30 DW PRO DUO WIFI V2 9. Insert the sound absorbing material into the 9. Insert the sound absorbing material into the air duct from the outside.
  • Page 11 RV 30/50 (D)W Pro WiFi V2 SIKU CONNECTION TO POWER MAINS AND CONTROL BEFORE STARTING ANY WORK WITH THE DEVICE, SWITCH OFF THE POWER SUPPLY. ELECTRICAL CONNECTIONS MAY ONLY BE CARRIED OUT BY AN AUTHORIZED SPECIALIST! THE BASIC ELECTRICAL DATA OF THE DEVICE IS LISTED ON THE MANUFACTURER LABEL.
  • Page 12 ON: the ventilator is running at the first speed in the Standby mode. SETUP OF AIR FLOW DIRECTION IN VENTILATION MODE WITH RUNNING VENTILATORS FOR SIKU RV 50 W PRO WIFI V2 OFF: the ventilator runs in the extract mode.
  • Page 13 Regeneration mode SIKU RV 50 W Pro WiFi V2 Rotation direction of the fan changes once in 70 seconds. Heat regeneration is accomplished in the Regeneration mode. To enable operation of the ventilators in opposite directions change the position of the DIP switch No.
  • Page 14 If several interconnected ventilators are running in the same network, in case of alarm shutdown of one SIKU RV 50 W Pro WiFi V2 ventilator, the Master-Unit and all the other ventilators of this series will stop. The alarm display of the faulty ventilation system flashes.
  • Page 15 Press any speed setting button to deactivate the timer or press the timer control button once again. VENTILATOR CONTROL WITH MOBILE APPLICATION To control the system via the mobile device, install the SIKU RV WiFi app. SIKU RV WIFI - APP STORE SIKU RV WIFI PLAY MARKET •...
  • Page 16 CONNECTION OF MOBILE APPLICATION TO THE VENTILATOR To control the ventilation system, download the SIKU RV WiFi program and install it on the mobile device. By default, the ventilation system works like a WiFi access point. Connect the mobile device to the WiFi access point with the name (FAN + 16 characters of the serial number), as shown on the housing under the External coverage specified.
  • Page 17 This operation mode enables heat regeneration. Supply mode In this mode the SIKU RV 50 W Pro WiFi V2 ventilator runs exclusively in the supply mode. The ventilator SIKU RV 30 DW Pro Duo WiFi V2 goes to the Ventilation mode. Night mode Activation of the first speed timer (the default setting is 8 hours, adjustable in the menu Settings - Timers).
  • Page 18 The “Party” timer sets transition time to the high speed after activation of the Party mode (4 hours by default). The turn-off delay timer for the „Boost“ mode defines switch delay to the high speed after actuation of any sensor and reset of the sensor to the standard status. siku.at siku.at...
  • Page 19 RV 30/50 (D)W Pro WiFi V2 SIKU SENSOR SETUP To set up sensor operation via the mobile application go to Note: for activation / Menu - Settings -Sensors. Deactivating the sensors and Humidity sensor: actuation of the humidity sensor. setting the Sensor...
  • Page 20 Master unit via the Wi-Fi Sensor-actuated operation connection. The Master unit is controlled via the The SIKU RV 50 W Pro WiFi V2 ventilators respond to mobile application, remote control or the sensor the signal from the sensors in the Master mode only.
  • Page 21 RV 30/50 (D)W Pro WiFi V2 SIKU WI-FI PARAMETER SETUP Setup of the Wi-Fi parameters is only possible on Master units. To set up ventilator Wi-Fi parameters via the mobile app go to Menu - Connection - WI-FI setup. Press the Receive button to display the current Wi-Fi settings.
  • Page 22 Mobilgerät Mobilgerät mobile device mobile device Master Slave Nr. 1 Slave Nr. 2 Slave No.1 Slave No.N Master Zusätzlicher WLAN-Zugangspunkt extra wireless acess point Mobilgerät Mobilgerät mobile device mobile device Slave Nr.N+1 Slave Nr.N+N Slave No.N+1 Slave No.N+N siku.at siku.at...
  • Page 23 RV 30/50 (D)W Pro WiFi V2 SIKU CONNECTING MASTER AND SLAVE VENTILATORS WHILE COMPLETING THE CONNECTION MAKE SURE THAT THE SLAVED VENTILATORS ARE WITHIN WI-FI COVERAGE OF THE MASTER VENTILATOR. To connect a Master and a Slave unit, set the DIP switches on each ventilator to Master or the Slave position (see page 13).
  • Page 24 The battery is located on the control circuit board. Power off the ventilator to replace the battery, remove the front panel and the cover protecting the control circuit board. Remove the battery and install the new one. Battery type: CR1220. siku.at siku.at...
  • Page 25 RV 30/50 (D)W Pro WiFi V2 SIKU CLOUD SERVER CONNECTION The ventilators can be controlled using the mobile app via a cloud server connection. This functions enables control of a single or multiple ventilators connected according to Diagram 2 over any distance using the mobile app connected to the Internet.
  • Page 26 The front panel incorporates an operating LED indicator. During the dark time the indicator light intensity drops down. AIR FLOW BLOCKING FOR THE SIKU RV 30 DW PRO DUO WIFI V2 Press the side tabs to detach the front part of the...
  • Page 27 Turn off the ventilator using the remote control or the buttons on the indoor unit. Then turn the power completely off. SIKU RV 50 W PRO WIFI V2 1. Press the side locks on the inner panel to separate the front section.
  • Page 28 • After the set filter replacement periodicity (90 days) has expired the Filter indicator starts glowing. For the SIKU RV 50 C Pro Comfo V2 unit the filter timer is reset once the cartridge connector is disconnected from the circuit board. Reset the filter timer for the SIKU RV 30 C Pro Duo Comfo V2 unit by turning the DIP switch 8 off and back on again.
  • Page 29 RV 30/50 (D)W Pro WiFi V2 SIKU POSSIBLE REASONS AND TROUBLESHOOTING PROBLEM POSSIBLE TROUBLESHOOTING Make sure the power supply line is connected No power supply. correctly, otherwise troubleshoot the connection When switching on error. the ventilator, the fan does not Turn the ventilator off.
  • Page 30 Failure to submit the user’s manual with the unit purchase date stamp. • Missing payment paperwork certifying the unit purchase. THE WARRANTY CLAIMS CAN ONLY BE MADE IF THE DEVICE, A PROOF OF PURCHASE AND THE OPERATING INSTRUCTIONS IN WHICH THE DATE OF PURCHASE IS NOTED ARE PRESENT. siku.at siku.at...
  • Page 31 This is to certify acceptance of the complete unit delivery with the user’s manual. The warranty terms are acknowledged and accepted. CUSTOMER‘S SIGNATURE Seller‘s Stamp INSTALLATION CERTIFICATE The SIKU RV _____________ unit has been connected to power mains pursuant to the requirements stated in the present user’s manual. SELLER ADDRESS PHONE NUMBER INSTALLATION TECHNICAN‘S FULL...