WIRING
3.3
Main circuit terminal specifications
3.3.1
Terminal arrangement of the main circuit terminal, power supply and the motor
wiring
Three-phase 400V class
FR-D740-012(SC) to 080(SC)
Jumper
N/- P/+
R/L1 S/L2 T/L3
PR
Power supply
Single-phase 200V class
FR-D720S-008(SC) to 042(SC)
Screw size (M3.5)
L1
N
Power supply
NOTE
Make sure the power cables are connected to the R/L1, S/L2, T/L3. (Phase need not be matched.) Never connect the
power cable to the U, V, W of the inverter. Doing so will damage the inverter.
Connect the motor to U, V, W. Turning ON the forward rotation switch (signal) at this time rotates the motor
counterclockwise when viewed from the load shaft.
6
Screw size (M4)
IM
Screw size
(M4)
Motor
Jumper
-
+
PR
Screw size
IM
(M3.5)
Motor
FR-D740-120(SC), 160(SC)
Screw size (M4)
Jumper
R/L1 S/L2 T/L3
N/-
P/+ PR
Power supply
FR-D720S-070(SC) and 100(SC)
Jumper
-
+
Screw size (M4)
L1 N
PR
Power supply
Screw size
(M4)
IM
Motor
IM
Screw size
(M4)
Motor