Champion 201319 Operator's Manual page 41

4500w dual fuel electric start inverter generator
Table of Contents

Advertisement

201319 - 4500W DUAL FUEL ELECTRIC START INVERTER GENERATOR
Problem
Engine hunts or falters.
Engine will not stop.
Repeated circuit breaker tripping.
For other issues and technical support:
Technical Support Team
Toll Free 1-877-338-0999
support@championpowerequipment.com
Cause
Engine governor defective.
Dirty fuel valve.
Carburetor is dirty and running lean.
Choke in wrong position.
Propane valve is still open.
Overload.
Faulty power cords or device.
Circuit breaker still too hot.
41
TROUbLESHOOTING
Solution
Contact the help line.
Clean the fuel valve.
Contact the help line.
Move EZ Start Dial to the RUN position.
Turn the propane valve to the CLOSED position on
the tank.
Review load and adjust. See "Connecting
Electrical Loads."
Check for damaged, bare or frayed wires. Replace
defective device.
Let unit sit for 5 mins.