Champion 201110 Operator's Manual

Champion 201110 Operator's Manual

9200w electric start generator

Advertisement

Quick Links

OPERATOR'S MANUAL
MODEL #201110
9200W ELECTRIC START GENERATOR
REGISTER YOUR PRODUCT ONLINE
at championpowerequipment.com
or visit championpowerequipment.com
SAVE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do
so could result in serious injury. This manual should remain with the product.
Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication, but are subject to change without notice.
This product meets the requirements of the PGMA (Portable Generator Manufacturers' Association) standard ANSI/PGMA G300-2018 (Safety and Performance of
Portable Generators).
Covered by one or more of the following U.S. Patent Numbers: 10,862,414 and other U.S. and foreign patents pending.
REV 20221123
Champion Power Equipment, Inc., Santa Fe Springs, CA USA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 201110 and is the answer not in the manual?

Questions and answers

Summary of Contents for Champion 201110

  • Page 1 This product meets the requirements of the PGMA (Portable Generator Manufacturers’ Association) standard ANSI/PGMA G300-2018 (Safety and Performance of Portable Generators). Covered by one or more of the following U.S. Patent Numbers: 10,862,414 and other U.S. and foreign patents pending. REV 20221123 Champion Power Equipment, Inc., Santa Fe Springs, CA USA...
  • Page 2 CARBON MONOXIDE SAFETY: THE BIG PICTURE As the only safe way to use a portable generator, taking your generator outside is absolutely mandatory to keep your family safe from carbon monoxide. But there’s even more you can do. By educating yourself about all carbon monoxide risks, you’ll be better prepared to protect CARBON MONOXIDE K ILLS your family from this colorless, oderless threat.
  • Page 3: Table Of Contents

    TAbLE Of CONTENTS 201110 - 9200W ELECTRIC START GENERATOR TAbLE Of CONTENTS Maintenance ..........Cleaning the Generator .......... Introduction ........... Changing the Engine Oil .........
  • Page 4: Introduction

    201110 - 9200W ELECTRIC START GENERATOR INTRODUCTION SAfETY DEfINITIONS Congratulations on your purchase of a Champion Power Equipment The purpose of safety symbols is to attract your attention to possible dangers. The safety symbols, and their explanations, (CPE) product. CPE designs, builds, and supports all of our products to strict specifications and guidelines.
  • Page 5: Important Safety Instructions

    DO NOT use electrical cords that are worn, damaged or frayed. recreational vehicle. Use only Champion electrical cords for proper application. DO NOT allow exhaust fumes to enter a confined area through DO NOT operate generator in wet weather.
  • Page 6 IMPORTANT SAfETY INSTRUCTIONS 201110 - 9200W ELECTRIC START GENERATOR WARNING CAUTION   Spark from removed spark plug wire can result in fire or Exceeding the generator’s running capacity can damage the electrical shock. generator and/or electrical devices connected to it.
  • Page 7: Fuel Safety

    IMPORTANT SAfETY INSTRUCTIONS 201110 - 9200W ELECTRIC START GENERATOR fuel Safety When operating the generator: DO NOT move or tip the generator during operation. DANGER  When transporting or servicing the generator: GASOLINE AND GASOLINE VAPORS ARE HIGHLY Always check that the fuel valve is in the OFF position and the FLAMMABLE AND EXPLOSIVE.
  • Page 8: Safety And Dataplate Labels

    E: updated utilisez-le to utilisez la APAGADO AUTOMÁTICO – USTED DEBE: This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for outside parties without the explicit consent of Champion Power Equipment.
  • Page 9: Safety Symbols

    IMPORTANT SAfETY INSTRUCTIONS 201110 - 9200W ELECTRIC START GENERATOR Safety Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
  • Page 10: Operation Symbols

    IMPORTANT SAfETY INSTRUCTIONS 201110 - 9200W ELECTRIC START GENERATOR Operation Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
  • Page 11: Quickstart Label Symbols

    3. Turn the fuel valve to the “OFF” position. doors and intake ventilation covers. This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for outside parties without the explicit consent of Champion Power Equipment.
  • Page 12: Controls And Features

    CONTROLS AND fEATURES 201110 - 9200W ELECTRIC START GENERATOR CONTROLS AND fEATURES Read this operator’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. Generator 1. Gasoline Tank – 7.7 gal. (29.1 L) 10.
  • Page 13: Control Panel

    CONTROLS AND fEATURES 201110 - 9200W ELECTRIC START GENERATOR Control Panel 1. Ignition Switch – Used to START or STOP the generator. RECEPTACLES 2. Intelligauge – Four mode digital meter for displaying voltage, 120/240V AC, 30A Locking (NEMA L14-30R) frequency, run time, and total run time.
  • Page 14: Intelligauge

    CONTROLS AND fEATURES 201110 - 9200W ELECTRIC START GENERATOR Intelligauge Four mode digital meter for displaying voltage, frequency, run time, and total run time. Multi-colored LED indicated CO shutoff or fault. MODE DESCRIPTION Output voltage of the generator. Example: 120 volts Voltage (V) Output frequency in hertz.
  • Page 15: Parts Included

    CONTROLS AND fEATURES 201110 - 9200W ELECTRIC START GENERATOR Parts Included Accessories Engine Oil ........37.2 fl. oz. (1100 ml) Oil Funnel .
  • Page 16: Assembly

    ASSEMbLY 201110 - 9200W ELECTRIC START GENERATOR ASSEMbLY Install the Support Leg 1. Attach the support leg (E) to the generator frame with flange Your generator requires some assembly. It must be properly bolts (F) and flange lock nuts (G).
  • Page 17: Add Fuel

    ASSEMbLY 201110 - 9200W ELECTRIC START GENERATOR NOTICE NOTICE   The recommended oil type for typical use is 10W-30 Once oil has been added, a visual check should show oil about automotive oil. However, using the listed conventional oils 1-2 threads from running out of the fill hole.
  • Page 18 ASSEMbLY 201110 - 9200W ELECTRIC START GENERATOR Use clean, fresh, regular unleaded gasoline with a minimum CAUTION  octane rating of 87 and an ethanol content of 10% or less by volume. y b c Use unleaded gasoline with a minimum octane rating of 87 and an ethanol content of 10% or less by volume.
  • Page 19: Grounding

    B: Updated dieline C: Deleted “25 ft./7 m” This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for outside parties without the explicit consent of Champion Power Equipment.
  • Page 20: Generator Location

    OPERATION 201110 - 9200W ELECTRIC START GENERATOR Generator Location NOTICE  WARNING This blinking does not indicate CO Shield is working, as CO  Shield is working at all times the generator is running. Also, NEVER operate the generator inside any building, garage,...
  • Page 21: Surge Protection

    OPERATION 201110 - 9200W ELECTRIC START GENERATOR Electric Start WARNING  1. Move the choke lever to the “CHOKE” position. Do not expose to rain or use in damp locations. 1a. For restarting a warm engine, move the choke lever to Keep all objects a minimum of 5 feet (1.5m) away from the...
  • Page 22 OPERATION 201110 - 9200W ELECTRIC START GENERATOR Manual Start 4. Do not over-choke. As soon as engine starts, move the choke lever to the “RUN” position over a 2-5 second duration. 1. Push the ignition switch to the “ON” position.
  • Page 23: Battery

    OPERATION 201110 - 9200W ELECTRIC START GENERATOR battery Do Not Overload Generator Capacity NOTICE  Follow these simple steps to calculate the running and starting The supplied 12V battery does re-charge while the engine is watts necessary for your purposes: running, but it is also recommended that the battery be fully 1.
  • Page 24: Stopping The Engine

    OPERATION 201110 - 9200W ELECTRIC START GENERATOR Stopping the Engine To ensure proper operation of the GFCI duplex, perform this test monthly: 1. Turn off and unplug all connected electrical loads. Never start 1. With the generator running, plug a lamp into the GFCI or stop the generator with electrical devices plugged in or receptacle.
  • Page 25: Moving The Generator

    MAINTENANCE 201110 - 9200W ELECTRIC START GENERATOR Moving the Generator To alleviate high altitude issues other than the natural power loss, CPE can provide a high altitude carburetor main jet. The alternative main jet and installation instructions can be obtained CAUTION ...
  • Page 26: Cleaning The Generator

    MAINTENANCE 201110 - 9200W ELECTRIC START GENERATOR The owner/operator is responsible for all periodic maintenance. 3. Replace the oil drain bolt. Complete all scheduled maintenance in a timely manner. 4. Add oil according to Add Engine Oil in Assembly section.
  • Page 27: Cleaning The Air Filter

    MAINTENANCE 201110 - 9200W ELECTRIC START GENERATOR Cleaning the Air filter CAUTION  1. Remove the snap-on cover holding the air filter to the Failure to clean the spark arrestor will result in degraded assembly. engine performance. NOTICE  Federal and local laws and administrative requirements indicate when and where spark arrestors are required.
  • Page 28: Maintenance Schedule

    STORAGE 201110 - 9200W ELECTRIC START GENERATOR Disconnect the Battery EVERY 100 HOURS OR ANNUALLY 1. Pull two halves of battery connector apart. — Change oil — Clean/adjust spark plug — Clean spark arrestor — Clean fuel valve filter* EVERY 250 HOURS —...
  • Page 29: Long Term Storage (Over 1 Year)

    STORAGE 201110 - 9200W ELECTRIC START GENERATOR Long Term Storage (over 1 year) 4. Start and run the generator for 10 minutes so the treated gasoline cycles through the fuel system. For storage over 1 year, the gasoline tank and carburetor must be 5.
  • Page 30: Specifications

    SPECIfICATIONS 201110 - 9200W ELECTRIC START GENERATOR SPECIfICATIONS Recommended Engine Oil Type 10W-30 Generator Specifications 5W-30 10W-40 Generator Model ......... .. 201110 5W-30 Full Synthetic Start Type ..
  • Page 31: Troubleshooting

    TROUbLESHOOTING 201110 - 9200W ELECTRIC START GENERATOR TROUbLESHOOTING Problem Cause Solution No fuel. Add fuel. Faulty spark plug. Clean and adjust spark plug or replace. Fill crankcase to the proper level. Low oil level. Place generator on a flat, level surface.
  • Page 32 TROUbLESHOOTING 201110 - 9200W ELECTRIC START GENERATOR Problem Cause Solution Poor cord connection. Check all connections. Circuit breaker is open. Reset circuit breaker. Check all circuit breakers. Faulty brush assembly. Replace brush assembly (Service Center). Loose wiring. Inspect and tighten wiring connections.
  • Page 33 To complete registration you will need to include a copy of the – Problems caused by parts that are not original Champion purchase receipt as proof of original purchase. Proof of purchase Power Equipment parts.
  • Page 34 THE UNITED STATES ENVIRONMENTAL PROTECTION AGENCY (U.S. EPA) AND THE CALIFORNIA AIR RESOURCES BOARD (CARB) EMISSION CONTROL SYSTEM WARRANTY Your Champion Power Equipment (CPE) engine complies with both the U.S. EPA and state of California Air Resources Board (CARB) Exhaust and Evaporative emissions regulations.
  • Page 35 EXHAUST AND EVAPORATIVE EMISSION CONTROL SYSTEM WARRANTY The following are specific provisions relative to your Exhaust and Evaporative Emission Control System (ECS) Warranty Coverage. 1. APPLICABILITY: This warranty shall apply to 1995 and later model year California small off-road engines (SORE) (for other states, 1997 and later model year engines).
  • Page 36 You must take your CPE engine or the product on which it is installed, along with your warranty registration card or other proof of original purchase date, at your expense, to any Champion Power Equipment dealer who is authorized by Champion Power Equipment, Inc. to sell and service that CPE product during his normal business hours.

Table of Contents