SAVE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do
so could result in serious injury. This manual should remain with the product.
Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication, but are subject to change without notice.
This product is rated in accordance with PGMA (Portable Generator Manufacturers' Association) standard ANSI/PGMA G300-2018 (Safety and Performance of
Portable Generators).
REV 20220713
Champion Power Equipment, Inc., Santa Fe Springs, CA USA
Page 1
Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication, but are subject to change without notice. This product is rated in accordance with PGMA (Portable Generator Manufacturers’ Association) standard ANSI/PGMA G300-2018 (Safety and Performance of Portable Generators). REV 20220713 Champion Power Equipment, Inc., Santa Fe Springs, CA USA...
Page 2
CARBON MONOXIDE SAFETY: THE BIG PICTURE As the only safe way to use a portable generator, taking your generator outside is absolutely mandatory to keep your family safe from carbon monoxide. But there’s even more you can do. By educating yourself about all carbon monoxide risks, you’ll be better prepared to protect CARBON MONOXIDE K ILLS your family from this colorless, oderless threat.
INTRODUCTION 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR INTRODUCTION SAFETY DEFINITIONS Congratulations on your purchase of a Champion Power Equipment The purpose of safety symbols is to attract your attention to possible dangers. The safety symbols, and their explanations, (CPE) product.
IMPORTANT SAFETY INSTRUCTIONS 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR IMPORTANT SAFETY INSTRUCTIONS DANGER Operate equipment with guards in place. WARNING Rotating parts can entangle hands, feet, hair, clothing and/or Cancer and Reproductive Harm – www.P65Warnings.ca.gov accessories.
Page 6
IMPORTANT SAFETY INSTRUCTIONS 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR WARNING CAUTION Spark from removed spark plug wire can result in fire or Start the generator and allow the engine to stabilize before electrical shock. connecting electrical loads.
IMPORTANT SAFETY INSTRUCTIONS 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR Fuel Safety When adding or removing gasoline: DO NOT light or smoke cigarettes. DANGER Turn the generator off and let cool for at least two minutes before removing the gasoline cap.
IMPORTANT SAFETY INSTRUCTIONS 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR Lithium-ion battery Safety When storing the generator/battery: – Always check that the battery connectors between the inverter Electrolyte inside the battery is harmful to skin and eyes. If the and the battery are unplugged and placed away from the battery leaks and electrolyte gets in your eyes, do not rub them.
2mm safe margin; to be printed on white substrate B: delete “25 ft/7m” This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for outside parties without the explicit consent of Champion Power Equipment.
IMPORTANT SAFETY INSTRUCTIONS 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR Safety Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
Page 11
IMPORTANT SAFETY INSTRUCTIONS 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR SYMBOL MEANING This product uses lithium-ion (Li-ion) batteries. Local, state, or federal laws may prohibit disposal of batteries in ordinary trash. Consult your local waste authority for information regarding available recycling and/or disposal options.
IMPORTANT SAFETY INSTRUCTIONS 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR Operation Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
Propane (LPG) in Assembly section and Starting the Engine: This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for Propane (LPG) in the Operation section.
CONTROLS AND FEATURES 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR CONTROLS AND FEATURES Read this operator’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference.
CONTROLS AND FEATURES 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR Control Panel 1. Intelligauge with Power Meter – See Intelligauge with RECEPTACLES Power Meter section. (2×) 120V AC, 20A (NEMA 5-20R) 2. Ignition Switch – Used to START the generator.
CONTROLS AND FEATURES 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR Intelligauge with Power Meter The meter is divided into two separate displays. The LCD displays each mode for several seconds and then automatically cycles through. The Power Meter LED displays output in percent (%) with 100% at the top.
CONTROLS AND FEATURES 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR Parts Included Accessories Engine Oil ........16.9 fl. oz. (500 ml) Oil Funnel ............
ASSEMbLY 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR ASSEMbLY Connect the battery 1. Remove the non recoil side maintenance cover by removing Your generator requires some assembly. It must be properly the two screws with a Phillips head screw driver serviced with fuel and oil before operation.
Page 19
ASSEMbLY 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR 5. Check engine oil level before each use and add as needed. NOTICE OIL DIP STICK OIL DIP STICK The recommended oil type for typical use is 5W-30 automotive oil. However, using the listed conventional oils shown in the “Recommended Engine Oil Type”...
ASSEMbLY 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR Add Fuel: Gasoline 3. The approximate fuel level is shown on the fuel gauge on top of the fuel tank. DANGER Empty Full Gasoline vapors are highly flammable and extremely explosive.
ASSEMbLY 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR NOTICE The generator engine works well with 10% or less ethanol blended gasoline. When using ethanol-gasoline blends there are some issues worth noting: – Ethanol-gasoline blends can absorb more water than gasoline alone.
2mm safe margin; to be printed on white substrate B: delete “25 ft/7m” This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for outside parties without the explicit consent of Champion Power Equipment.
Page 23
OPERATION 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR NOTICE CO Shield will detect the accumulation of carbon monoxide ® (CO) from other fuel burning sources such as engine powered equipment, or propane heaters used in the area of operation. If...
OPERATION 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR Generator Location WARNING WARNING Do not expose to rain or use in damp locations. Keep all objects a minimum of 5 feet (1.5m) away from the NEVER operate the generator inside any building, garage, generator at all times.
Page 25
OPERATION 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR 4. Pull the recoil cord slowly until resistance is felt and then pull 4. Pull the recoil cord slowly until resistance is felt and then pull rapidly. rapidly. Electric Start 5.
OPERATION 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR Starting the Engine: Propane (LPG) 5. Do not over-choke. As soon as engine starts, turn the EZ Start dial to the “RUN” position. NOTICE Turn the generator off before attempting to switch from gasoline to LPG operation.
Page 27
OPERATION 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR 6. Turn the EZ Start Dial to the “RUN” position. 5. Pull the recoil cord slowly until resistance is felt and then pull rapidly. Electric Start 7. Pull the recoil cord slowly until resistance is felt and then pull rapidly.
OPERATION 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR 7. Press and hold the yellow ignition switch on the EZ Start NOTICE Dial toward the center of the dial for up to 5 seconds or until started. Accumulation of frost on LPG cylinder and regulators is common during operation and normally is not an indication of a problem.
OPERATION 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR 4. If the generator power output is cut off due to an overload WARNING condition indicated by the AC overload blinking light, lower the load by unplugging one or more items, then press the...
Eco Mode should be off. This section has had a template updated. Use below text The Champion model 201080 is parallel ready and can be operated in parallel with another Champion unit to increase the 12V DC Regulated Automotive Style Outlet total available electrical power.
OPERATION 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR Moving the Generator 3. Turn the EZ Start dial to the “STOP” position. CAUTION – NEVER lift or carry the generator using the folding handle. – NEVER tilt sideways while moving the generator.
MAINTENANCE 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR To alleviate high altitude issues other than the natural power The owner/operator is responsible for all periodic maintenance. loss, CPE can provide a high altitude carburetor main jet. The Complete all scheduled maintenance in a timely manner.
MAINTENANCE 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR 4. Ensure the oil drain hose is lower than the engine and allow 6. Refer to the spark plug types in Specifications when replacing the oil to drain completely into an appropriate container.
MAINTENANCE 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR Cleaning the Spark Arrestor Adjusting the Governor 1. Allow the engine to cool completely before servicing the spark WARNING arrestor. Tampering with the factory set governor will void your 2.
STORAGE 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR 1. Remove the battery from the generator. EVERY 100 HOURS OR ANNUALLY 2. Charge battery following the battery charger’s instructions. Change oil 3. After charging, leave the battery for 0.5 to 1 hour before ...
STORAGE 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR 4. Run the generator for 10 minutes so the treated gasoline 6. When gasoline stops flowing from the clear tube, rotate drain cycles through the fuel system and carburetor. screw clockwise until tight. Properly dispose of the drained gasoline according to local regulations or guidelines.
SPECIFICATIONS 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR SPECIFICATIONS Oil Specifications DO NOT OVERFILL. Generator Specifications Type ..........*See following chart Generator Model ......... ..
SPECIFICATIONS 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR Temperature Specifications Manual Starting Temperature Range (°F/°C) ........5 to 104/-15 to 40 Electric Starting Temperature Range (°F/°C)
TROUbLESHOOTING 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR TROUbLESHOOTING Problem Cause Solution No fuel. Add fuel. Faulty spark plug. Clean and adjust spark plug or replace. Fill crankcase to the proper level. Low oil level. Place generator on a flat, level surface.
Page 40
TROUbLESHOOTING 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR Problem Cause Solution Move generator to an open, outdoor area. Point exhaust away from people and buildings. Move to fresh air and get medical help if sick, dizzy, or weak.
Page 41
TROUbLESHOOTING 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR Problem Cause Solution DUAL FUEL MODELS ONLY: Engine will Turn the propane valve to the CLOSED position on Propane valve is still open. not stop. the tank. Review load and adjust. See “Connecting Overload.
WARRANTY 201080 - 4650W DUAL FUEL ELECTRIC START INVERTER GENERATOR WARRANTY* Other Exclusions This warranty excludes: CHAMPION POWER EQUIPMENT – Cosmetic defects such as paint, decals, etc. 3 YEAR LIMITED WARRANTY – Wear items such as filter elements, o-rings, etc.
Page 43
AND THE UNITED STATES ENVIRONMENTAL PROTECTION AGENCY (U.S. EPA) EMISSION CONTROL SYSTEM WARRANTY Your Champion Power Equipment (CPE) engine complies with U.S. EPA emissions regulations. YOUR WARRANTY RIGHTS AND OBLIGATIONS: The US EPA and CPE are pleased to explain the Federal Emission Control Systems Warranty on your 2022 small off-road engine (SORE) and engine powered equipment.
Page 44
EMISSION CONTROL SYSTEM WARRANTY The following are specific provisions relative to your Emission Control System (ECS) Warranty Coverage. 1. APPLICABILITY: This warranty shall apply to 1997 and later model year small off-road engines (SORE). The ECS Warranty Period shall begin on the date the new engine or equipment is delivered to its original, end-use purchaser, and shall continue for 24 consecutive months thereafter.
Page 45
You must take your CPE engine or the product on which it is installed, along with your warranty registration card or other proof of original purchase date, at your expense, to any Champion Power Equipment dealer who is authorized by Champion Power Equipment, Inc. to sell and service that CPE product during his normal business hours.