Error Messages

Various error messages will be displayed when there is a problem with the soldering station. If the
following message is displayed, see the trouble shooting guide.
– – – System Error
S – E Sensor Error
Flash of the Temperature Display
Heater Error
WARNING! * Disconnect the power plug before servicing. Failure to do so may result in electric
shock.
* If the power cord is damaged, it must be replaced by the manufacturer or
its service agent or similarity qualified person in order to avoid hazard.
After the power has been turned on, the system checks the
memory and the programs. If an abnormality is found,
– – – will be displayed, and all operations will be
completely stopped.
If there is a possibility of a failure in the sensor or
anywhere in the sensor circuit S – E will be displayed and
power to the soldering iron will be cut off.
If power is being sent to soldering iron and the tip
temperature goes below the heater—error temperature—
tolerance setting, the temperature display will flash. This
indicates the possibility of a heater malfunction.