Page 1
User Manual Rechargeable Li-ion Battery System Lynx Home F Series G2 V1.1 -2023 -10-30...
Page 2
Copyright Statement User Manual V1.1-2023-10-30 Trademarks and other GoodWe trademarks are trademarks of GoodWe Technologies Co.,Ltd. All other trademarks or registered trademarks mentioned in this manual are owned by the company. NOTICE The information in this user manual is subject to change due to product updates or other reasons.
CONTENT User Manual V1.1-2023-10-30 CONTENT 1 About This Manual ............... 01 1.1 Applicable Model ..................01 1.2 Target Audience ..................01 1.3 Symbol Definition ..................01 1.4 Updates ......................02 2 Safety Precaution ..............01 2.1 General Safety ..................... 01 2.2 Battery Safety ....................
Page 4
CONTENT User Manual V1.1-2023-10-30 8 Maintenance ............... 27 8.1 Power OFF the Battery System ..............27 8.2 Routine Maintenance ................. 28 8.3 Common Problem Handling ..............28 8.4 System Troubleshooting ................29 9 Technical Parameters............31...
All the installers and users have to be familiar with the product features, functions, and safety precautions. This manual is subject to update without notice. For more product details and latest documents, visit https://en.goodwe.com. 1.1 Applicable Model This manual applies to the listed model below: •...
Page 6
01 About This Manual User Manual V1.1-2023-10-30 1.4 Updates The latest document contains all the updates made in earlier issues. V1.1 2023-10-30 • The installation position of the terminal resistor has been updated from being placed in the accessory package to being built-in at the communication port. •...
• Strictly follow the installation, operation, and configuration instructions in this guide and user manual. The manufacturer shall not be liable for equipment damage personal injury if you do not follow the instructions. For more warranty details, please visit https:// en.goodwe.com/warranty.
02 Safety Precaution User Manual V1.1-2023-10-30 2.2 Battery Safety DANGER • High voltage exists during the battery system running. Ensure that the equipment has been powered off to avoid the risk of electric shock before operating the device in the system.
Page 9
02 Safety Precaution User Manual V1.1-2023-10-30 CAUTION • Protect the battery system from damage during transportation and storage. • The transportation must be carried out by trained professionals. All operations during the process have to be recorded. • Keep the equipment stable to avoid dumping, which can result in equipment damage and personal injuries.
• The fire cannot be put out by water or ABC dry powder extinguisher. Firefighters are required to wear full protective clothing and self-contained breathing apparatus. 2.4 EU Declaration of Conformity GoodWe Technologies Co., Ltd. hereby declares that the product without wireless communication modules sold in the European market meets the requirements of the following directives: •...
• LX F25.6- H-20 • LX F28.8- H-20 Model Referring to Description Lynx Home F Series Series code Usable energy • 9.6: the usable energy of the battery system is 9.6kWh. • 12.8: the usable energy of the battery system is 12.8kWh.
Page 12
03 Product Introduction User Manual V1.1-2023-10-30 Usable energy NOTICE • The battery system supports capacity expansion. A maximum of nine battery modules can be used to extend the usable energy of the battery system. Expand the battery system capacity in strict compliance with the expansion requirements. Contact the dealer or manufacturer for more details.
AC circuit Battery breaker breaker (optional) Loads Battery Battery system 1 system N (2≤N≤8) Approved inverter list Scan the QR code below or visit the official website to get the Approved Battery Options Statement. GoodWe Inverter Inverter...
03 Product Introduction User Manual V1.1-2023-10-30 3.3 Appearance Battery system Power control unit Battery base Parts Description Battery base Battery module 3 to 9 battery modules can be connected in the battery system. Battery serial Connects the battery module to the next module or to the connection interface power control unit.
Page 15
03 Product Introduction User Manual V1.1-2023-10-30 Parts Description Power control unit serial connection Connects the power control unit to a battery module. interface • SOC indicator: indicates the SOC status of the battery. SOC indicator • Multi-function button indicator • Black start button: When there is no PV power generation in the PV system and the power grid is abnormal, long press the multi-function button for 5s to 10s, and then release it to start the battery system.
04 Check and Storage User Manual V1.1-2023-10-30 4 Check and Storage 4.1 Check Before Receiving Check the following items before receiving the product. 1. Check the outer packing box for damage, such as holes, cracks, deformation, and other signs of equipment damage. Do not unpack the contents from the box and contact the supplier as soon as possible if any damage is found.
04 Check and Storage User Manual V1.1-2023-10-30 Battery module Battery module x 1 4.3 Storage If the equipment is not to be installed or used immediately, please ensure that the storage environment meets the following requirements: 1. Do not unpack the outer package or throw the desiccant away. 2.
05 System Installation User Manual V1.1-2023-10-30 5 System Installation 5.1 Installation Requirements Installation Environment Requirements 1. Do not install the equipment in a place near flammable, explosive, or corrosive materials. 2. Do not install the equipment in a place that is easy to touch, especially within children’s reach. High temperature exists when the equipment is working.
Page 19
05 System Installation User Manual V1.1-2023-10-30 Mounting Support Requirements • The mounting support shall be nonflammable and fireproof. • Install the equipment on a surface that is solid enough to bear the product weight. • Put the battery system near the wall and install the locking brackets to prevent the battery from falling down.
05 System Installation User Manual V1.1-2023-10-30 5.2 Installing the Battery System 5.2.1 Moving the Equipment CAUTION • Operations such as transportation, shipment, installation and so on shall in compliance with the laws and regulations of the country or region where the inverter is located. •...
Page 21
05 System Installation User Manual V1.1-2023-10-30 M5*12 Diameter: 10mm Depth: 80mm 4N·m ST5.5*70 10N·m M5*12 4N·m...
Page 22
05 System Installation User Manual V1.1-2023-10-30 WARNING • Remove the PCU after marking the drilling positions to avoid damage to the unit when drilling holes using the drill. • Cover the battery system with a cardboard to prevent foreign matters when drilling holes, which may damage the system.
06 Electrical Connection User Manual V1.1-2023-10-30 6 Electrical Connection 6.1 Safety Precaution DANGER • High voltage exists during the battery system running. Ensure that the equipment has been powered off to avoid the risk of electric shock before operating the device in the system.
06 Electrical Connection User Manual V1.1-2023-10-30 6.2 Electrical Connection Single Battery System NOTICE • Please ensure that the COM1 communication port is connected to the inverter, and the COM2 communication port is equipped with a terminal resistor when the PCU leaving the factory.
06 Electrical Connection User Manual V1.1-2023-10-30 6.4 Connecting the Power Cable WARNING • The DC cable should be prepared by the customer. Recommended specifications: • Type: single-core outdoor copper cable • Conductor cross-sectional area S: S=6mm or S=16mm • When the cross-sectional area range of the conductor is 6mm , a 6mm DC connector (included in the deliverables) should be used.
06 Electrical Connection User Manual V1.1-2023-10-30 Model: YQK-70 Click 6.5 Connecting the Communication Cable WARNING • If the communication cable between the inverter and the battery system is supplied by the inverter manufacturer, you can decide whether to use the supplied cable or not according to the actual situation.
Page 28
06 Electrical Connection User Manual V1.1-2023-10-30 WARNING • Detailed requirements for communication cable connection and termination resistor installation can be obtained in the system wiring network. This chapter only describes the connection method of communication cables and port definitions. • If the termination resistor is not installed, the Interlock Failure will occur, and the battery system cannot work correctly.
07 Equipment Commissioning User Manual V1.1-2023-10-30 7 System Operation 7.1 Check Before Power ON Check the following items before power on to avoid the battery system being damaged. Check Item The system is firmly installed in a clean place where is well-ventilated and easy to operate.
07 Equipment Commissioning User Manual V1.1-2023-10-30 Circuit breaker Circuit (Optional) breaker Inverter (Optional) Battery system 1 Battery system 2 Battery system N 2≤N≤ 8 NOTICE • Black start button: When there is no PV power generation in the PV system and the power grid is abnormal, long press the multi-button for 5s to 10s, and then release it to start the battery system.
Page 31
NOTICE Select the wrong battery model may cause system failure. Ensure that the battery model is right. Lynx Home F Series G2 Select the battery brand and battery model that is actually connected to the...
07 Equipment Commissioning User Manual V1.1-2023-10-30 7.4 Indicator Status Normal status SOC indicator status Button Indicator Battery system status status SOC indicator indicates SOC of the Green light blink 1 The battery system is in standby battery system. time/s status. SOC<5% Green light blink 2 5%≤SOC<25%...
08 Maintenance User Manual V1.1-2023-10-30 8 Maintenance 8.1 Power OFF the Battery System DANGER • Power off the battery system before operations and maintenance. Otherwise, the equipment may be damaged or electric shocks may occur. • Strictly follow the power off requirements to avoid damaging the system. NOTICE •...
08 Maintenance User Manual V1.1-2023-10-30 Method II: Step 1:Turn off the inverter in the system following the instructions in the user manual of the inverter. Step 2:Long press the multi-function button indicator for more than 15s and release it, make sure that the SOC indicator and multi-function button indicator of the PCU are off.
08 Maintenance User Manual V1.1-2023-10-30 1. Check if the terminal resistor of COM2 port is installed correctly. 2. Check if the communication cables are The red button correct. indicator light 3. Check if the inverter is working blinks, the SOC light 1.
Page 36
08 Maintenance User Manual V1.1-2023-10-30 Overcurrent Restart the battery. Contact the after-sale service if the Charging problem persists. Overcurrent Restart the battery. Contact the after-sale service if the Discharging problem persists. Low Insulation Contact the after-sale service. Resistance Voltage Restart the battery and leave it for 12 hours. Contact Difference the after-sale service if the problem persists Exception...
Need help?
Do you have a question about the Lynx Home F Series and is the answer not in the manual?
Questions and answers