Goodwe Lynx Home F G2 Series User Manual

Goodwe Lynx Home F G2 Series User Manual

Rechargeable li-ion battery system
Hide thumbs Also See for Lynx Home F G2 Series:

Advertisement

Quick Links

User Manual
Rechargeable Li-ion Battery System
Lynx Home F Series
G2
V1.0-2023-05-20

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Lynx Home F G2 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Goodwe Lynx Home F G2 Series

  • Page 1 User Manual Rechargeable Li-ion Battery System Lynx Home F Series V1.0-2023-05-20...
  • Page 2 Copyright Statement User Manual V1.0-2023-05-20 Trademarks and other GOODWE trademarks are trademarks of GoodWe Technologies Co.,Ltd. All other trademarks or registered trademarks mentioned in this manual are owned by the company. NOTICE The information in this user manual is subject to change due to product updates or other reasons.
  • Page 3: Table Of Contents

    CONTENT User Manual V1.0-2023-05-20 Content 1 About This Manual ............... 01 1.1 Applicable Model ..................01 1.2 Target Audience ....................01 1.3 Symbol Definition ..................01 1.4 Updates ......................02 2 Safety Precaution ..............01 2.1 General Safety ....................01 2.2 Battery Safety ....................01 2.3 Emergency Measures ...................03 EU Declaration of Conformity ..............03 3 Product Introduction ............
  • Page 4 CONTENT User Manual V1.0-2023-05-20 8 Maintenance ............... 25 8.1 Power OFF the Battery System ..............25 8.2 Routine Maintenance ...................26 8.3 Troubleshooting ...................26 9 Technical Parameters............28...
  • Page 5: About This Manual

    All the installers and users have to be familiar with the product features, functions, and safety precautions. This manual is subject to update without notice. For more product details and latest documents, visit https://en.goodwe.com/. 1.1 Applicable Model This manual applies to the listed models below: •...
  • Page 6: Updates

    Disclaimer User Manual V1.0-2023-05-20 1.4 Updates The latest document contains all the updates made in earlier issues. V1.0 5/20/2023 • First Issue...
  • Page 7: Safety Precaution

    • Strictly follow the installation, operation, and configuration instructions in this manual. The manufacturer shall not be liable for equipment damage or personal injury if you do not follow the instructions. For more warranty details, please visit: https://www.goodwe.com/ support-service/warranty-related.
  • Page 8: Battery Safety

    02 Safety Precaution User Manual V1.0-2023-05-20 2.2 Battery Safety DANGER • High voltage exists during the battery system running. Power off the battery system before any operations to avoid danger. Strictly follow all safety precautions outlined in this manual and safety labels on the equipment during the operation. •...
  • Page 9 02 Safety Precaution User Manual V1.0-2023-05-20 Label Description Potential risks exist. Wear proper Install the equipment away from personal protective equipment open flames or fire sources. before any operations. High voltage hazard. High voltage exists during the equipment’ s Keep the equipment away from running.
  • Page 10: Emergency Measures

    2.4 EU Declaration of Conformity GoodWe Technologies Co., Ltd. hereby declares that the inverter without wireless communication modules sold in the European market meets the requirements of the following directives: •...
  • Page 11: Product Introduction

    03 Product Introduction User Manual V1.0-2023-05-20 3 Product Introduction 3.1 Product Overview Intended usage The battery system, which consists of a power control unit (PCU for short) and battery modules, can store and release the electric energy according to the requirements of the solar energy storage system.
  • Page 12 03 Product Introduction User Manual V1.0-2023-05-20 Usable energy description NOTICE • The battery system supports capacity expansion. A maximum of nine battery modules can be used to extend the usable energy of the battery system. Expand the battery system capacity in strict compliance with the expansion requirements. Contact the dealer or manufacturer for more details.
  • Page 13: Application Scenarios

    AC circuit breaker Battery breaker (optional) Loads Battery Battery system 1 system N (2≤N≤ 8) Approved inverter list Scan the QR code below or visit the official website to get the Approved Battery Options Statement. GE Inverter GoodWe Inverter...
  • Page 14: Appearance

    03 Product Introduction User Manual V1.0-2023-05-20 3.3 Appearance Battery system Power control unit Battery base Parts Descriptions Battery base Battery module 3 to 9 battery modules can be connected in the battery system. Battery serial Connects the battery module to the next module or to the power connection control unit.
  • Page 15 03 Product Introduction User Manual V1.0-2023-05-20 Parts Descriptions • SOC indicator: indicates the SOC status of the battery. SOC indicator • Multi-function button indicator • Black start button: In the PV system, the inverter may not work properly when there is no PV power generation and the utility grid is abnormal.
  • Page 16: Check And Storage

    04 Check and Storage User Manual V1.0-2023-05-20 4 Check and Storage 4.1 Check Before Receiving Check the following items before receiving the product. 1. Check the outer packing box for damage, such as holes, cracks, deformation, and other signs of equipment damage. Do not unpack the package and contact the supplier as soon as possible if any damage is found.
  • Page 17: Storage

    04 Check and Storage User Manual V1.0-2023-05-20 Battery module Battery module x 1 4.3 Storage If the equipment is not to be installed or used immediately, please ensure that the storage environment meets the following requirements: 1. Do not unpack the outer packing box or throw the desiccant away. 2.
  • Page 18: System Installation

    05 System Installation User Manual V1.0-2023-05-20 5 System Installation 5.1 Installation Requirements Installation Environment Requirements 1. Do not install the equipment in a place near flammable, explosive, or corrosive materials. 2. Do not install the equipment in a place that is easy to touch, especially within children’ s reach. High temperature exists when the equipment is working.
  • Page 19 05 System Installation User Manual V1.0-2023-05-20 Mounting Support Requirements • The mounting support shall be nonflammable and fireproof. • Install the equipment on a surface that is solid enough to bear the product weight. • Put the battery system near the wall and install the locking brackets to prevent the battery from falling down.
  • Page 20: Installing The Battery System

    05 System Installation User Manual V1.0-2023-05-20 5.2 Installing the Battery System 5.2.1 Moving the Equipment CAUTION • Operations such as transportation, turnover, installation and so on must meet the requirements of the laws and regulations of the country or region where it is located. •...
  • Page 21 05 System Installation User Manual V1.0-2023-05-20 M5*12 Diameter: 8mm Depth: 80mm 4N·m ST5.5*70 10N·m M5*12 4N·m...
  • Page 22 05 System Installation User Manual V1.0-2023-05-20 WARNING • Remove the PCU after marking the drilling positions to avoid damage to the unit when drilling holes using the drill. • Cover the battery system with a cardboard to prevent foreign matters when drilling holes, which may damage the system.
  • Page 23: Electrical Connection

    06 Electrical Connection User Manual V1.0-2023-05-20 6 Electrical Connection 6.1 Safety Precaution DANGER • High voltage exists during the battery system running. Power off the battery system before any operations to avoid danger. Strictly follow all safety precautions outlined in this manual and safety labels on the equipment during the operation.
  • Page 24: Electrical Connection

    06 Electrical Connection User Manual V1.0-2023-05-20 6.2 Electrical Connection Single Battery System NOTICE • The COM1 and COM2 ports are of the same function. Make sure that one communication port is connected to the inverter and the other is fitted with a termination resistor. The battery system cannot work properly if the termination resistor is not installed.
  • Page 25 06 Electrical Connection User Manual V1.0-2023-05-20 Parallel Connected Battery Systems NOTICE • A max of eight battery systems can be parallel connected in one energy storage system. Ensure that the usable energy of each battery system is the same. • The COM1 and COM2 ports are of the same function.
  • Page 26: Connecting The Pe Cable

    06 Electrical Connection User Manual V1.0-2023-05-20 6.3 Connecting the PE cable NOTICE • Connect the PE cable first before installing the equipment. Disconnect the PE cable before dismantling the equipment. • Make sure that the drawing force of the cable after crimping is greater than 400N. •...
  • Page 27: Connecting The Power Cable

    06 Electrical Connection User Manual V1.0-2023-05-20 6.4 Connecting the Power Cable WARNING • The DC cable should be prepared by the customer. Recommended specifications: • Type: single-core outdoor copper cable • Conductor cross-sectional area S: 4mm ≤S≤6mm or 14mm ≤S≤16mm •...
  • Page 28: Connecting The Communication Cable

    06 Electrical Connection User Manual V1.0-2023-05-20 6.5 Connecting the Communication Cable WARNING • If the communication cable between the inverter and the battery system is supplied by the inverter manufacturer, you can decide whether to use the supplied cable or not according to the actual situation.
  • Page 29 06 Electrical Connection User Manual V1.0-2023-05-20 WARNING • Detailed requirements for communication cable connection and termination resistor installation can be obtained in the system wiring network. This chapter only describes the connection method of communication cables and port definitions. • If the termination resistor is not installed, the Interlock Failure will occur, and the battery system cannot work correctly.
  • Page 30: System Operation

    07 Equipment Commissioning User Manual V1.0-2023-05-20 7 System Operation 7.1 Check Before Power ON Check the following items before power on to avoid the battery system being damaged. Checking Item The system is firmly installed in a clean place where is well-ventilated and easy to operate.
  • Page 31: Setting The Battery Parameters

    07 Equipment Commissioning User Manual V1.0-2023-05-20 NOTICE After powering on the battery system, ensure that the inverter communicates with the battery system properly within 15 minutes. If the inverter cannot communicate properly with the battery system, the battery system switch will automatically disconnect and power off the battery system.
  • Page 32 07 Equipment Commissioning User Manual V1.0-2023-05-20 Step 3: Tap Home > Parameters > Basic Setting to set the basic parameters. Follow the prompts to select and set the battery model. NOTICE Select the wrong battery model may cause system failure. Ensure that the battery model is right. Lynx Home F Series G2 Select the battery brand and battery model that is...
  • Page 33: Indicator Status

    07 Equipment Commissioning User Manual V1.0-2023-05-20 7.4 Indicator Status Normal status SOC indicator status Button Indicator Battery system status status SOC indicator indicates SOC of the Green light blink 1 The battery system is in battery system. time/s standby status SOC<5% Green light blink 2 5%≤SOC<25%...
  • Page 34: Maintenance

    08 Maintenance User Manual V1.0-2023-05-20 8 Maintenance 8.1 Power OFF the Battery System DANGER • Power off the battery system before operations and maintenance. Otherwise, the equipment may be damaged or electric shocks may occur. • Strictly follow the power off requirements to avoid damaging the system. NOTICE •...
  • Page 35: Routine Maintenance

    08 Maintenance User Manual V1.0-2023-05-20 Method II: Step 1:Turn off the inverter in the system following the instructions in the user manual of the inverter. Step 2:Long press the multi-function button indicator for more than 15s, and make sure that the SOC indicator and multi-function button indicator of the PCU are off.
  • Page 36 08 Maintenance User Manual V1.0-2023-05-20 SOC indicator Fault Solutions status Battery Power off and wait for 2 hours. Contact the after-sale Overvoltage service if the problem persists. Battery Contact the after-sale service. Undervoltage High Cell Power off and wait for 2 hours. Contact the after-sale Temperature service if the problem persists.
  • Page 37 08 Maintenance User Manual V1.0-2023-05-20 Air Switch Contact the after-sale service. Adhesion Restart the battery. Contact the after-sale service if the Precharge Failure problem persists. Relay Power off and wait for 2 hours. Contact the after-sale Overtemperature service if the problem persists. Current Diverter Power off and wait for 2 hours.
  • Page 38: Technical Parameters

    09 Technical Parameters User Manual V1.0-2023-05-20 9 Technical Parameters Technical Parameters LX F9.6-H-20 LX F12.8-H-20 LX F16.0-H-20 LX F19.2-H-20 Usable Energy (kWh) 12.8 16.0 19.2 Battery Module LX F3.2-20: 64V 3.2kWh Number of Modules Cell Type LFP (LiFePO Nominal Voltage (V) Operating Voltage Range (V) 172.2 ~ 216.6 229.6 ~ 288.8...
  • Page 39 09 Technical Parameters User Manual V1.0-2023-05-20 Technical Parameters LX F22.4-H-20 LX F25.6-H-20 LX F28.8-H-20 Usable Energy (kWh) 22.4 25.6 28.8 Battery Module LX F3.2-20: 64V 3.2kWh Number of Modules Cell Type LFP (LiFePO Nominal Voltage (V) Operating Voltage Range (V) 401.8 ~ 505.4 459.2 ~ 577.6 516.6 ~ 649.8...
  • Page 40 Official Website GoodWe Technologies Co.,Ltd. No. 90 Zijin Rd., New District, Suzhou, 215011, China T: 400--998--1212 www.goodwe.com Contact Information service@goodwe.com...

Table of Contents