  • Page 1 162 405 19-4 2023-10-04 Providing sustainable energy solutions worldwide Installation and Maintenance manual CTC AT 1 / AT 2 Hot Water Storage Tanks Important! • Read carefully before use, keep for future reference. • Translation of the original instructions.
  • Page 3 Installation and Maintenance Manual CTC AT 1 / AT 2 Hot Water Storage Tanks...
  • Page 5 ___________________________________ 15. CTC AT 1.750/50 (3 bar) ____________________________________ 16. CTC AT 1. 750/50 (6 bar) ___________________________________ 17. CTC AT 1. 750/75 (3 bar) ___________________________________ 18. CTC AT 1. 750/75 (6 bar) ___________________________________ For your own reference Fill in the information below. It may come in useful if anything should happen.
  • Page 7 Checklist The checklist must always be completed by the installation engineer • In the event of servicing, this document may need to be provided • Installation must always be carried out according to the Installation and Maintenance Instructions • Installation must always be carried out according to professional standards Following installation, the unit must be inspected and functional checks performed as indicated below: Pipe installation...
  • Page 8 Congratulations on your new product! You have just purchased a CTC Hot Water Storage Tank (CTC AT), which we hope you will be very pleased with. CTC’s Hot Water Storage Tanks are coil tanks and volume tanks of 300- 1000 litres and are designed for almost all types of energy sources. They are available in several models and sizes, and can also be combined to fit most heating systems and properties.
  • Page 9: Safety Instructions

    Safety instructions Turn off the power with an omnipolar switch before doing any work on the product. The product must be connected to protective earth. The product is classified as IPX1. The product must not be rinsed with water. When handling the product with a hoist ring or similar device, make sure that the lifting equipment, eyebolts and other parts are not damaged.
  • Page 10: Important To Remember

    Important to remember! Check the following in particular on delivery and installation: Transportation • Transport the CTC Hot Water Storage Tank to the installation site before The product must removing the packaging. The product must be transported and stored in an be transported and upright position.
  • Page 11: Operation And Maintenance

    2. Operation and Maintenance Once CTC Hot Water Storage Tank has been installed, you and your installer should together check that the system is in perfect operating condition. Let the installer show you how the system works and how it should be maintained. Bleed the radiators after approximately three days of operation and refill the water if necessary.
  • Page 12 3. Removing and fi tting insulation These instructions apply to the following hot water storage tank models: • CTC AT 1. 500/50 (6 bar) • CTC AT 1. 750/50 (3 bar) • CTC AT 1. 750/75 (3 bar) • CTC AT 2. 750 (3 bar) •...
  • Page 13: Pipe Installation

    4. Pipe installation The installation must be carried out in accordance with current heating and DHW standards. The product must be connected to an expansion vessel in an open or closed system. Do not forget to flush the radiator system before connection.
  • Page 14 5. CTC AT 2. 300 (3 bar) DETAIL A SCALE 1 : 10 CTC Emblem 589393301 Enertechs part nr for CTC Emblem is Borö art.nr: 304-589913001 positioned according to drawing Enertech art.nr: 589913001 RSK nr: 6519936 CONNECTIONS Technical Data GTIN nr: 7333077102104 1.
  • Page 15 6. CTC AT 2. 500 (3 bar) DETAIL A Rev.Nr: Typ av änd SCALE 1 : 10 DN32 PUR-isolering 1738 DN50 (5x) 1711 1588 DN20 (3x) 1492 1387 1277 Enbart volymtank/Ackumulator Manufacturing label CTC Emblem 584233301 Enertechs part nr for CTC Emblem is positioned according to drawing Technical Data Borö...
  • Page 16 7. CTC AT 2. 500 (6 bar) Rev.Nr: Typ av ändring DN32 Expansion/Avluftning Rev.Nr: Rev.Nr: Typ av ändring Typ av ändring 1772 DN32 DN32 1748 DN50 Expansion/Avluftning Expansion/Avluftning Tillopp från värmekälla 1772 1772 DN20 1465 Termometer/Givare 1748 1748 1360 DN50 DN50 DN50 Alt tillopp från värmekälla Tillopp från värmekälla...
  • Page 17 8. CTC AT 2. 750 (3 bar) Rev.Nr: Typ av ändring DN32 inv Dimensions 1817 1791 1810 DN50 (5x) 1784 DN20 (3x) 1481 1376 1515 1266 UTUS 1410 • Inge 1300 1061 1015 Label "Importer UK" Dimen Manufacturing label Technical Data Borö...
  • Page 18 9. CTC AT 2. 750 (6 bar) Rev.Nr: Typ av ändring DN32 inv Rev.Nr: Typ av ändring 1817 1791 DN50 (5x) DN32 inv DN20 (3x) Dimensions 1481 1817 1376 1791 1817 1266 UTUSTNING: DN50 (5x) 1791 • Ingen DN20 (3x) 1061 1481 1376 1481...
  • Page 19 10. CTC AT 2. 1000 (3 bar) DN32 Dimension 1907 1907 DN80 (4x) 1560 1560 1360 1360 DN20 (4x) 1160 1160 Ø890 1090 Ø1090 1101 1. DN32: Expansion/Bleeding (A) 4 x DN80: Supply/Return/Immersion heater outlet (D/F/H/J) 4 x DN20: Draining/Thermometer (E/G/I/K) Article number 590642301 Max operating pressure (PS) Heating system...
  • Page 20 11. CTC AT 1. 300/25 (3 bar) DETAIL A SCALE 1 : 10 Manufacturing label CTC Emblem CONNECTIONS 589393301 Enertechs part nr for CTC Emblem is positioned according to drawing 1. Temperature sensor thermowell Ø7 Borö art.nr: 304-589912001 2. Immersion heater outlet (2x)- DN50 Enertech art.nr:...
  • Page 21 12. CTC AT 1. 500/25 (3 bar) Rev.Nr: Typ av ändrin DN32 DETAIL A SCALE 1 : 10 1741 DN50 (5x) 1711 DN20 (3x) 1492 1387 1277 Varmvattenslinga 25m (Yta 6m²) Label "Importer UK" Manufacturing label CTC Emblem 584233301 Enertechs art. nr for CTC Emblem is positioned according drawing Borö...
  • Page 22 13. CTC AT 1. 500/50 (3 bar) Rev.Nr: Typ av ändr DN32 1741 DN50 (5x) 1711 DN20 (3x) 1492 1387 1277 Varmvattenslinga 2x25m (Yta 12 m²) Label "Importer UK" Manufacturing label CTC Embelm 584233301 Enertechs art. nr for CTC Emblem is...
  • Page 23 Rev.Nr: Typ av ändring DN32 14. CTC AT 1. 500/50 (6 bar) Expansion/Avluftning Rev.Nr: Typ av ändring 1772 1748 DN50 DN32 Tillopp från värmekälla Expansion/Avluftning 1495 DN20 1772 1465 Termometer/Givare DN50 1360 1748 DN50 Alt tillopp från värmekälla Tillopp från värmekälla 1250 Varmvattenslingor 2x25m (Ø22)
  • Page 24 15. CTC AT 1.750/50 (3 bar) Rev.Nr: Typ av ändring DN32 inv 1817 Ø22 Dimensions 1791 DN50 (5x) 1810 1511 DN20 (3x) 1784 1481 Varmvattenslingor 2x25m 2 x 25 m 1376 1515 (Yta tot 12m²) 1266 1515 UTUSTN • Varmva...
  • Page 25 Rev.Nr: Typ av ändring 16. CTC AT 1. 750/50 (6 bar) DN32 inv 1817 Rev.Nr: Typ av ändring 1791 DN50 (5x) 1511 DN20 (3x) DN32 inv 1481 Varmvattenslingor 2x25m 1376 1817 (Yta tot 12m²) Dimensions Ø22 1791 1266 UTUSTNING: 1817 DN50 (5x) •...
  • Page 26 17. CTC AT 1. 750/75 (3 bar) Rev.Nr: Typ av ändring DN32 inv 1817 Dimensions Ø22 1791 1810 DN50 (5x) 1511 1784 DN20 (3x) 1481 1515 Varmvattenslingor 3x25m 1376 3 x 25 m (Yta tot 18m²) 1515 1266 • 1410...
  • Page 27 Rev.Nr: Typ av ändring 18. CTC AT 1. 750/75 (6 bar) DN32 inv 1817 Rev.Nr: Typ av ändring 1791 DN50 (5x) 1511 DN20 (3x) DN32 inv 1481 Varmvattenslingor 3x25m 1376 1817 (Yta tot 18m²) Dimensions Ø22 1791 1266 UTUSTNING: DN50 (5x) 1817 •...
  • Page 28 162 405 19-4 2023-10-04 Enertech AB. PO Box 309 SE-341 26 Ljungby Sweden. www.ctc.se, www.ctc-heating.com...