Summary of Contents for CTC Union CTC Accumulator Tank 1. 300/20
Page 1
162 405 19-1 2021-04-19 Providing sustainable energy solutions worldwide Installation and Maintenance Manual CTC Hot Water Storage Tanks IMPORTANT • Read carefully before use, keep for future reference • Translation of the original instructions.
Page 3
Installation and Maintenance Manual CTC Hot Water Storage Tanks...
Table of Contents Safety instructions _______________________________________________________ Important to remember! ____________________________________ Transportation __________________________________________________ Positioning ______________________________________________________ Recycling ________________________________________________________ After commissioning _________________________________________ Operation and Maintenance _____________________________ Removing and fitting insulation ________________________ Pipe installation __________________________________________________ CTC Hot Water Storage Tank 2. 300 ________________ CTC Hot Water Storage Tank 2. 500 (3 bar) ____ CTC Hot Water Storage Tank 2. 500 (6 bar) ____...
Page 7
Checklist The checklist must always be completed by the installation engineer • In the event of servicing, this document may need to be provided • Installation must always be carried out according to the Installation and Maintenance Instructions • Installation must always be carried out according to professional standards Following installation, the unit must be inspected and functional checks performed as indicated below: Pipe installation...
Page 8
Congratulations on your new product! You have just purchased a CTC Hot Water Storage Tank, which we hope you will be very pleased with. CTC’s Hot Water Storage Tanks are coil tanks and volume tanks of 300-750 litres and are designed for almost all types of energy sources.
Safety instructions Säkerhetsföreskrifter Bryt strömmen med allpolig brytare före alla ingrepp i produkten. Produkten måste kopplas till skyddsjord Produkten klassas som IPX1. Produkten får ej spolas med vatten. Vid hantering av produkten med lyftögla eller liknande se till att lyftdon, öglor och övriga delar är oskadade.
Important to remember! Check the following in particular on delivery and installation: Transportation • Transport the CTC Hot Water Storage Tank to the installation site before The product must removing the packaging. The product must be transported and stored in an be transported and upright position.
2. Operation and Maintenance Once CTC Hot Water Storage Tank has been installed, you and your installer should together check that the system is in perfect operating condition. Let the installer show you how the system works and how it should be maintained. Bleed the radiators after approximately three days of operation and refill the water if necessary.
3. Removing and fi tting insulation These instructions apply to the following hot water storage tank models: • CTC Hot Water Storage Tank 1. 500/50 (6 bar) • CTC Hot Water Storage Tank 1. 750/50 • CTC Hot Water Storage Tank 1. 750/75 •...
4. Pipe installation The installation must be carried out in accordance with current heating and DHW standards. See BBR (Boverkets Byggregler) and DHW Recommendations (Varm- och hetvattenanvisningar (VVA 1993)). The product must be connected to an expansion vessel in an open or closed system. Do not forget to flush the radiator system before connection.
5. CTC Hot Water Storage Tank 2. 300 DETAIL A SCALE 1 : 10 Manufacturing label CTC Emblem 584233301 Enertechs part nr for CTC Emblem is positioned according to drawing Technical Data Borö art nr: 304-588354301-E17 Enertech art nr: 588354301 Borö AB is responsible for the correct technical data on decals RSK nr: 6519840 Borö...
6. CTC Hot Water Storage Tank 2. 500 (3 bar) Manufacturing label CTC Embelm 584233301 Enertechs art. nr for CTC Emblem is positioned according drawing Technical Data Borö AB is responsible for the correct technical data on decals Borö AB is responsible for assuming stackable allowable products Delivery performance 4 pcs packing label, one on each side 1 pc.
Rev.Nr: Typ av ändring 7. CTC Hot Water Storage Tank 2. 500 DN32 Expansion/Avluftning (6 bar) Rev.Nr: 1772 1748 DN50 DN32 Tillopp från värmekälla Expansion/Avluftning DN20 1465 1772 Termometer/Givare 1360 DN50 1748 Alt tillopp från värmekälla DN50 1250 Tillopp från värmekälla UTUSTNING: DN20 1465...
8. CTC Hot Water Storage Tank 2. 750 (3 bar) Technical Data Borö AB is responsible for the correct technical data on decals Borö AB is responsible for assuming stackable allowable products Delivery performance Distr till 4 pcs packing label, one on each side Ytjämnh 1 pc.
DETAIL A 10. CTC Hot Water Storage Tank 1. 300/20 SCALE 1 : 10 (Area: 6 m Manufacturing label CTC Emblem 584233301 Enertechs part. nr for CTC Emblem is positioned according drawing Technical Data Borö AB is responsible for the correct technical data on decals Borö...
11. CTC Hot Water Storage Tank 1. 500/25 DETAIL A SCALE 1 : 10 (Area: 6 m Manufacturing label CTC Emblem 584233301 Enertechs art. nr for CTC Emblem is positioned according drawing Technical Data Borö AB is responsible for the correct technical data on decals Borö...
12. CTC Hot Water Storage Tank 1. 500/50 (3 bar) (Total area: 12 m Manufacturing label Borö art nr: 501V-588349301 Enertech art nr: 588349301 RSK nr: 6519845 CTC Embelm GTIN nr: 7333077084622 584233301 Enertechs art. nr for CTC Emblem is positioned according drawing Technical Data Borö...
13. CTC Hot Water Storage Tank 1. 500/50 Rev.Nr: Typ av ändrin (6 bar) DN32 Expansion/Avluftning 1772 1748 DN50 Rev.Nr: Typ av ändring Tillopp från värmekälla DN32 1495 DN20 Expansion/Avluftning 1465 Termometer/Givare DN50 1360 Alt tillopp från värmekälla 1250 DN50 Varmvattenslingor 2x25m (Ø22) Tillopp från värmekälla (tot yta 12 m²) DN50...
14. CTC Hot Water Storage Tank 1.750/50 (3 bar) 5883 Manufacturing label Technical Data Borö AB is responsible for the correct technical data on decals Borö AB is responsible for assuming stackable allowable products Delivery performance Distr till/Antal 4 pcs packing label, one on each side 1 pc.
16. CTC Hot Water Storage Tank 1. 750/75 (3 bar) (Total area: 18 m 5883 Seri Manufacturing label Technical Data Borö AB is responsible for the correct technical data on decals Borö AB is responsible for assuming stackable allowable products Delivery performance Distr till/Antal 4 pcs packing label, one on each side...
Page 26
17. CTC Hot Water Storage Tank 1. 750/75 Rev.Nr: Typ av ändring Rev.Nr: Typ av ändring (6 bar) DN32 inv 1817 1791 DN32 inv DN50 (5x) 1817 1511 DN20 (3x) 1791 1481 DN50 (5x) Varmvattenslingor 3x25m 1376 (Yta tot 18m²) 1511 1266 DN20 (3x) UTUSTNING:...
Warranty conditions Garantibestämmelser Detta är en sammanställning av CTC’s garantibestämmelser som gäller tillsammans med AA VVS (Allmänna leveransbestämmelser avseende VVS- och VA-material för yrkesmässig verksamhet i Sverige. Bestämmelserna är utarbetade och tillhandahålls av VVS-Fabrikanternas Råd). Om anvisningarna i detta dokument ej följs är Enertechs åtaganden enligt dessa bestämmelser ej bindande.
Page 28
162 405 19-1 2021-04-19 Enertech AB. PO Box 309 SE-341 26 Ljungby Sweden. www.ctc.se, www.ctc-heating.com...
Need help?
Do you have a question about the CTC Accumulator Tank 1. 300/20 and is the answer not in the manual?
Questions and answers