External Power Signal; Compressed Air Supply Connections - Branson 900IW+ Series Operator's Manual

Integrated welders
Table of Contents

Advertisement

Rfaa
No - lubricated
air eunalg (3S 100 PSI)
Waterlog
with
draincock
3.4.5 External Power Signal
A 2-pin connector is provided. Use an optional J952 cable. This signal
provides a 0 - 5V signal to a maximum loading of 200k ohm resistive.
3.5 Compressed Air Supply Connections
It is important to prevent impurities and moisture from entering through
the air lines and damaging your equipment. To facilitate this when
installing your welder, use an air line hookup that includes a riser and
waterleg (see Figure 3-9 "Hooking up an Air Line"). Connect the air line to
a clean (5 micron), unlubricated, dry, compressed air supply — max. 100
psig/690 kPa, min. 35 psig/240 kPa. Use the supplied, self-draining air
filter with a 5-micron element.
Caution:
Permanent damage to the gauge may result if operated
above the maximum gauge reading (100 psig/690 kPa) or
below the minimum (35 psig/240 kPa).
Set the pressure regulator to zero before connecting or
disconnecting the air supply.
Figure 3-9
Hooking up
an Air Line
Installation
3-10
900IW+