Introduction Thank you for purchasing TPI products. The 285 is easy to use and built to last. It is backed by a three year limited warranty. Please visit www.testproductsintl.com to register your meter. Product Description The slim design 285 is a hand-held, auto ranging clamp-on DMM with Bluetooth output for use with the TPI View app.
Have someone check on you periodically if working alone. • Have a complete understanding of the circuit being measured. • Disconnect power to circuit, then connect test leads to the 285, then to circuit being measured. • NEVER Attempt to measure unknown high voltages.
Controls and Functions General Specifications 6000 count dual display LCD Display with backlight Max Voltage between input terminal and 1000VDC / 750VAC ground Operating Temperature 32°F to 113°F (0°C to 40°C) Storage Temperature -4°F to 140°F (-20°C to 60°C) Relative Humidity 80% non-condensing 6,562 feet maximum Altitude...
Page 7
Values display for some display area functions Not all icons shown are used with the 285 DC / AC Voltage Continuity Buzzer / Resistance Unique Icons Auto Power Off is active. Instrument powers off after Diode 15 minutes of inactivity. This feature can be disabled.
Measuring DC Volts Measuring AC Voltage Range: 0 to 1000VDC Range: 0 to 750VAC Warning! Warning! Do not attempt to make a voltage measurement of more Do not attempt to make a voltage measurement of more than 1000VDC or of a voltage level that is unknown. than 750VAC or of a voltage level that is unknown.
Measuring Resistance (Ohms) Measuring Continuity Range: 0 to 60MΩ Range: Buzzer sounds at <7Ω Warning! Warning! Do not attempt to make resistance measurements with Do not attempt to make a continuity measurement with the circuit energized. For best results, remove the resistor the circuit energized.
Measuring Diodes Measuring Capacitance Range: Approximate forward bias voltage of diode Range: 0 to 60mF Warning! Warning! Do not attempt to make capacitance measurements with Do not attempt to make diode measurements with the the circuit energized. Remove the capacitor from the circuit energized.
Measuring Temperature Measuring Frequency Range: -57.9°F to 1830°F (-49.9°C to 999°C) Range: 0 to 6MHz Warning! Note: Temperature measurements require use of the K- Do not attempt to make frequency measurements of Type thermocouple adapter and a K-Type thermocouple signals more than 600V or a voltage level that is probe.
Measuring AC Amperage Measuring DC Microamps Range: 0 to 600A AC Range: 0 to 600µA Warning! Warning! Do not attempt to make an amperage measurement of Do not attempt to make a DC Microamp measurement circuits with more than 600V CAT IV present. Instrument with the test leads connected in parallel with the circuit.
Once REL is active, auto range is deactivated. The 285 will beep and the LED next to the NCV key will 2. Measure a point that you want to use as the illuminate to indicate the presence of voltage.
In-Rush Current Mode (In-Rush) Bluetooth In-Rush mode is used on the AC Amps range to capture Note: To use the Bluetooth function, download the TPI motor start up current. When a motor starts there can be View app on your smart device.
°F. If needed, the default unit of measure can be set using the temperature function and Relative Mode. to °C. (Note: when measuring temperature, the unit of 1. As outlined on page 11, set the 285 up to make a measure can be changed by pressing the FUNCTION temperature measurement.
Page 16
Test Products International, Inc. 9615 SW Allen Blvd., Ste. 104 Beaverton, OR 97005 Tel: 503-520-9197 www.testproductsintl.com Test Products International, Ltd. 342 Bronte Road South, Unit #6 Milton Ontario Canada L9T 5B7 Tel: 905-693-8558 www.tpicanada.com Test Products International Europe Ltd. Rutherford Way Industrial Estate Rutherford Way Manor Royal Crawley...
Need help?
Do you have a question about the 285 and is the answer not in the manual?
Questions and answers