Faults - WIKA KSR KUEBLER AL-ADF Series Operating Instructions Manual

Float switch
Table of Contents

Advertisement

Available languages

Available languages

6. Faults

Fault
Float switch can-
not be attached in
the location in-
tended on the
container
No or undefined
switch function
Incorrect switch
point dimensions
KSR KUEBLER Betriebsanleitung Schwimmerschalter AL-ADF...
The most frequent causes for faults and the countermeas-
ures necessary are listed in the tables below.
Cause
Process connection of the
float switch does not fit with
the process connection of
the container.
Process connection on con-
tainer defective
Screw-in thread on float
switch defective
Electrical connection incor-
rect
Temperature contact defec-
tive
Reed contact defective
Float incorrectly installed
False ordering information
CAUTION!
Bodily injuries, property and environmental damages
If faults cannot be remedied with the help of the measures
listed above immediately decommission the device.
Ensure that there is no more pressure and protect
against accidental commissioning.
Contact the manufacturer.
In the event a return is necessary note the instructions
in Section 8.2 "Return".
Measure
Retrofitting of the container
Return to factory
Reworking of the thread or
replacement of the fastening
sleeve
Return to factory
See Section 5.3 "Electrical
Connection".
Check configuration with the
help of the circuit diagram.
Return to factory
Return to factory
Turn float around
Please contact the factory for
further information.
55