11. Safety devices

Type of
protection
Circuit
Current fuse (PCB*)
protection
Fan motor
Thermal protection program
protection
Thermal protection program
(Discharge temp.)
Thermal protection program
Compressor
(Compressor temp.)
protection
Thermal protection program
(Outdoor temp.)
(Only in COOL or DRY mode)
*PCB: Printed Circuit Board
Protection form
Activate
Reset
Activate
Reset
Activate
Reset
Activate
Reset
- 51 -
Model
AOBH27CMTA
250 V, 30 A
250 V, 3.15 A
250 V, 10 A × 2
122 ±9°C
Fan motor stop
+10
116
°C
-9
Fan motor restart
110°C
Compressor stop
After 7 minutes
Compressor restart
108 °C
Compressor stop
80 °C or less
Compressor restart
-20 °C
Compressor stop
-15 °C
Compressor restart