Precautions On Installation Of Indoor Unit - Gree Versati III GRS-CQ4.0PdG/NhH2-E Owner's Manual

Air-to-water heat pump
Table of Contents

Advertisement

Air-to-water Heat Pump All in One Versati
No.
Name
1
Leaving Water Pipe
2
Returning Water Pipe
3
Liquid-side Pipe
4
Gas-side Pipe
5
Gas-side Pipe

7.4 Precautions on installation of indoor unit

(1) Keep the indoor unit away from heat sources like heat sink and so on in the room as much as possible.
(2) Keep the indoor unit as close as possible to outdoor unit. Level distance between connection pipes cannot
exceed 20m(4.0~6.0kW) or 25m (8.0~10kW) and vertical distance cannot exceed 15m (4~10kW).
(3) A safety valve and a check valve are necessary at the inlet and outlet of demostic water pipes; otherwise it
would affect adversely the normal use of the unit.
GRS-CQ4.0PdG/NhH2-E(I), GRS-CQ6.0PdG/NhH2-E(I), GRS-CQ8.0PdG/
NhH2-E(I), GRS-CQ10PdG/NhH2-E(I), GRS-CQ12PdG/NhH2-E(I), GRS-
1/4
CQ14PdG/NhH2-E(I), GRS-CQ16PdG/NhH2-E(I), GRS-CQ8.0PdG/NhH2-M(I),
GRS-CQ10PdG/NhH2-M(I), GRS-CQ12PdG/NhH2-M(I), GRS-CQ14PdG/NhH2-
M(I), GRS-CQ16PdG/NhH2-M(I)
GRS-CQ8.0PdG/NhH2-M(I), GRS-CQ10PdG/NhH2-M(I), GRS-CQ4.0PdG/
1/2
NhH2-E(I), GRS-CQ6.0PdG/NhH2-E(I), GRS-CQ8.0PdG/NhH2-E(I), GRS-
CQ10PdG/NhH2-E(I)
GRS-CQ12PdG/NhH2-M(I), GRS-CQ14PdG/NhH2-M(I), GRS-CQ16PdG/NhH2-
5/8
M(I), GRS-CQ12PdG/NhH2-E(I), GRS-CQ14PdG/NhH2-E(I), GRS-CQ16PdG/
NhH2-E(I)
Tap water
Gas pipe
Liquid pipe
Communication cable
Remarks
1"Male BSP
1"Male BSP
Domestic hot water
Return water
Supply water
20
SPLIT
TYPE
Unit: inch