Table.10-2
The transmitting symbol"▲"does not blink
Fault
Check item
When you
Check whether the
press
batteries of remote
controller are low
ON/OFF
button, the
remote
controller
signal
cannot be
transmitted
Table.10-3
The temperature indicator doesn´t not light up
Fault
Check item
The
Check whether the
temperature
mode marked on the
indicator
screen is Supply Air
does not
light up
Table.10-4
The display disappears
Fault
Check item
After a while,
Check whether the time
the ON/OFF
set on the timer has
display
expired
disappears
After a while,
Check whether the time
the
set on the timer has
TIMING ON
expired
display
disappears
Table.10-5
No sound of receiving signal
Fault
Check item
When
When the ON/OFF button
pressing the
is pressed, check
ON/OFF
whether the signal
button,
transmitting part of the
the air
remote controller is
conditioner
aligned with the receiving
does not
part of the indoor unit.
raise the
Check whether the power
receiving
switch of the air
tone
conditioner is connected
properly
The buttons
Check the screen of the
of the
remote controller
remote
controller do
not respond

11. REPAIR

In case your air conditioner fails to operate normally, shut down the
unit and cut off the power supply promptly. Then contact the manfac-
turer distributor. Report the model, operation environment and fault
information of the air conditioner in detail, request for sending techni-
cians to repair, but do not fix it by yourself at your discretion.
cause
When the batteries
are exhausted, the
signals cannot be
transmitted
cause
In the Supply Air
mode, the temperature
cannot be set
cause
The air conditioner
stops running
because the set time
has expired
When it comes to the
set time of starting
operation of the air
conditioner, the air
conditioner will start
running automati-
cally, and the
corresponding display
will disappear.
cause
Align the signal
transmiting part of the
remote controller with
the receiving part of the
indoor unit. Then press
the ON/OFF button
repeatedly.The air
conditioner cannot
receive the signals of
the remote controller
because it is shut
down.
Lock buttons

12. TROUBLE SHOOTING

12.1 Duct type
Display
No.
All lamps flashing at 5Hz
1
Timer lamp flashing at 5Hz
2
Operation lamp
3
flashing at 5Hz
Defrosting lamp
4
flashing at 5Hz
Alarm lamp flashing at 5Hz
5
Operation lamp & Timer
6
lamp flashing at 5Hz
Infrared signal receiver
Operation lamp
Timer lamp
PRE-DEF indicator(cooling type)
or fan only indicator(cooling only type)
12.2 Floor type
No.
LED
E0
Eeprom error
1
2
T1 open circuit or short circuit
E1
E2
3
T2 open circuit or short circuit
4
P1
T2 low temp protection under cooling mode
P2
T2 high temp protection under heating mode
5
13 MODEL, SPECIFICATION & PARAMETERS
In case any parameters in the following table are changed, no
other notice will be given. The parameters specified on the
nameplate shall prevail.
The cooling capacity of the air conditioner is measured in a
standard environment where the indoor dry/wet bulb tempera-
ture is 27°C/19°C and the outdoor dry/wet bulb temperature is
35°C/24°C; and the actual cooling capacity changes with
the rise/fall of the indoor/outdoor environment temperature and
relative humidity.
The noise of the unit is measured in the semi noise suppression
lab according to the national standards, and the accuracy extent
is ±3dB(A).
Problem
The PRO terminal on PCB of
indoor unit without connected
to N-phase wire, or optical
coupler on PCB malfunction
Room temperature sensor
malfunction
Evaporator temperature
sensor malfunction
Condensator temperature
sensor malfunction
Water-level check malfunction
Eeprom malfunction
Manual Switch
Alarm lamp
Problem
NOTE
owner's manual
7