Technical Data - Husqvarna PG400 Operator's Manual

Hide thumbs Also See for PG400:
Table of Contents

Advertisement

Available languages

Available languages

Technical data

Motor Power, kW/hp
Rated current, A
Rated voltage, V
Weight, kg/lbs
Grinding width, mm/inch
Grinding pressure, kg/lbs
Rotation speed - grinding disc, rpm 1445
Noise emissions (see note 1)
Sound power level, measured dB(A)
Sound levels (see note 2)
Sound pressure level at the operators ear, dB(A)
Vibration levels (see note 3)
2
Handle right, m/s
2
Handle left, m/s
Note 1: Noise emission in the environment measured as sound power according to EN 60335-2-72. Expected
measurement uncertainty 2,5 dB(A).
Note 2: Sound pressure level according to EN 60335-2-72. Expected measurement uncertainty 4 dB(A).
Note 3: Vibration level according to EN 60335-2-72. Reported data for vibration level has a typical statistical dispersion
(standard deviation) of 1 m/s
20 – English
TECHNICAL DATA
PG400
(3-phase, 200-240V)
50 Hz
4,0/5,4
15
220-240
126/278
400/16
31-59/69-130 31-59/69-130 31-59/69-130 31-59/69-130 33-62/73-136
2
PG400
(3-phase, 400-480V)
60 Hz
50 Hz
4,8/6,5
4,0/5,4
15
9
220-240
400-480
126/278
126/278
400/16
400/16
1740
1445
98
84,7
6,5
5,2
PG400 (Single-
phase, 220-240V)
60 Hz
60 Hz
4,8/6,5
3,0/4,0
9
18
400-480
220-240
126/278
128/282
400/16
400/16
1740
1140

Advertisement

Table of Contents
loading

Table of Contents