Download Print this page

Setup And Operation - Watec WAT-3500 Operation Manual

1/2.8” multi-function compact high sensitivity analog camera
Hide thumbs Also See for WAT-3500:

Advertisement

Set-up and Operation
1) Ensure that the power to the camera and the peripheral equipment is turned off before making any connections.
2) Remove the lens mount cap from the camera and attach the CS-mount lens on "②LENS MOUNT" .
Use the option 30CMA-R (C-mount adaptor) when a C-mount lens isused.
3) Connect the iris control cable to "④DC-IRIS SOCKET" on the camera when a DC auto-iris lens is being used.
4) Insert the power plug of the power adaptor into "⑧POWER IN" on the back panel of the camera.
5) Turn on the power to the camera, monitor and all other allied equipment.
6) Connect "⑥VIDEO OUT Terminal" on the camera with a monitor using a coaxial cable with 75Ω impedance.
*When the image cannot be obtained on the monitor, or a problem occurs, check and follow the procedure mentioned in
the "Problems and Trouble Shooting" (P.5).
7) Adjust the focus and iris until optimal image clarity though the lens is achieved. If the picture is still out of focus, loosen
"③CS MOUNT SET SCREWS" with the supplied hexagon wrench to move the lens forwards until a fully focused is obtained.
Lens Type
Manual Lens
Motorized Zoom Lens
DC Auto-iris Lens
8) If the above operations do not provide sufficient images or if more detailed settings are required, set various functions on
the OSD menu. *To change camera functions on the OSD menu, connect the optional RC-01 (remote controller) to
"⑦REMOTE CONTROL TERMINAL".
Options
This product exerts the optimum performance with our recommended options. Please take a look at our website and catalog
introducing more options. Contact the distributor or dealer for purchase.
VARIOUS LENSES
We offer lenses maximizing the
performance of the camera.
SWI12-12-N-P5
A power supply adaptor (DC+12V)
supporting the camera.
VCHO-15S
Aluminum dripproof camera housing.
*IEC standard IPX5
Adjust the focus and iris to the best position on the lens.
Back focus is required via CS Mount.
Adjust the iris level on the camera, then adjust the focus on the lens.
Set the DC iris operation setting on the OSD menu, then adjust the focus on the lens.
30CMA-R
This lens mount adaptor is used to
convert a CS-mount to a C-mount.
RC-01
This controller is used to set various
functions on the screen.
Operation
| 04 |
3C2V ( BNC / BNC )
A coaxial cable supporting the camera
available in 2.5m, 3m, 5m or 10m.
MS50
With the coupler structure, the camera
can be adjusted to any desired angle.

Advertisement

loading

This manual is also suitable for:

Wat-2500