Setup
)
Press the END key to exit the EXT operating mode.
l
Press the PGM NAME key and use the cursor keys to
select the desired Parameter list. Then press ENT.
l
If necessary, edit the Parameter list as described below.
)
Change the machine Parameter MP721 0 to Programming
Station (input value 2).
l
Press END to exit the machine Parameter list. If you
cannot exit the machine Parameter list, proceed as
described below.
If the TNC at your machine is not equipped with the same
Software version as the programming
Station, the machine
Parameter list of the machine may have either too few or too
many Parameters. In this case you cannot yet exit the
machine Parameter list. After you've pressed the END key,
the TNC jumps to the nearest missing or unknown
parameters. You must first make the following corrections:
l
Machine Parameters that the programming
Station does
not recognize are moved to the right. Delete these
Parameters with DEL.
l
Machine Parameters that are not included in the list from
your machine show two question marks instead of the
input value. Replace the question marks with the Standard
input values from the list on page 9 and following
in this
manual.
l
Press END to exit the machine Parameter list.
28

Advertisement