Hob; Installation,12 - Hotpoint Ariston TQ 751 K GH/HA Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Installation
GB
! Before operating your new appliance please read this instruction booklet
carefully. It contains important information for safe use, installation and
care of the appliance.
! Please keep these operating instructions for future reference. Pass them
on to possible new owners of the appliance.
Positioning
! Keep packaging material out of the reach of children. It can become a
choking or suffocation hazard (see Precautions and tips).
! The appliance must be installed by a qualified professional according
to the instructions provided. Incorrect installation may cause harm to
people and animals or may damage property.
! This unit may be installed and used only in permanently ventilated
rooms in accordance with current national regulations. The following
requirements must be observed:
• The room must be equipped with an air extraction system that expels
any combustion fumes. This may consist of a hood or an electric fan
that automatically starts each time the appliance is switched on.
In a chimney stack or branched flue.
(exclusively for cooking appliances)
• The room must also allow proper air circulation, as air is needed for
combustion to occur normally. The flow of air must not be less than
2 m
/h per kW of installed power.
3
A
Examples of
ventilation holes
for comburant air.
Adjacent
Room to be
Room
Vented
Enlarging the ventilation slot
between window and floor.
• Liquid petroleum gas sinks to the floor as it is heavier than air.
Therefore, rooms containing LPG cylinders must also be equipped
with vents to allow gas to escape in the event of a leak. As a result
LPG cylinders, whether partially or completely full, must not be
installed or stored in rooms or storage areas that are below ground
level (cellars, etc.). It is advisable to keep only the cylinder being used
in the room, positioned so that it is not subject to heat produced by
external sources (ovens, fireplaces, stoves, etc. ) which could raise
the temperature of the cylinder above 50°C.
12
Directly to
the Outside
The air circulation system may take air
directly from the outside by means of a pipe
with an inner cross section of at least 100
cm
; the opening must not be vulnerable
2
to any type of blockages.
The system can also provide the air
needed for combustion indirectly, i.e. from
adjacent rooms fitted with air circulation
tubes as described above. However, these
rooms must not be communal rooms,
bedrooms or rooms that may present a
fire hazard.
Fitting the appliance
The following precautions must be taken when installing the hob:
• Kitchen cabinets adjacent to the appliance and taller than the top
of the hob must be at least 600 mm from the edge of the hob (see
figure).
• Hoods must be installed according to their relative installation
instruction manuals and at a minimum distance of 650 mm from the

hob.

• Place the wall cabinets adjacent to the hood at a minimum height of
420 mm from the hob (see figure).
If the hob is installed beneath a wall
cabinet, the latter must be situated at a
minimum of 700 mm above the hob.
600mm min.
• The installation cavity should have the dimensions indicated in the
figure.
Fastening hooks are provided, allowing you to fasten the hob to tops
that are between 20 and 40 mm thick. To ensure the hob is securely
fastened to the top, we recommend you use all the hooks provided.
• Before fastening the cooktop in place, position the seal (supplied)
along the perimeter of the countertop, as shown in the figure.
Hook fastening diagram
Hooking position for top H=20mm Hooking position for top H=30mm
Hooking position for top H=40mm
555 mm
Front
Back