Burner and nozzle specifications
Table 1
Burner
Reduced Fast (R)
Semi Fast (S)
Auxiliary (A)
Mini WOK (MW)
Supply pressures
*
At 15°C and 1013,25 mbar - dry gas
**
Propane
***
Butane
Natural
RR
MW
A
TQ 751K GH/HA
Diameter
Thermal Power
(mm)
kW (p.c.s.*)
Nomin.
Reduc.
100
2.60
0.70
75
1.65
0.40
55
1.00
0.40
110
3.50
1.50
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
P.C.S. = 50.37 MJ/Kg
P.C.S. = 49.47 MJ/Kg
P.C.S. = 37.78 MJ/m³
S
S
Liquid Gas
By-pass
Nozzle
1/100
1/100
(mm)
(mm)
***
39
80
189
28
64
120
28
50
73
61
91
254
28-30
20
35
Natural Gas
Flow*
Nozzle
Flow*
g/h
1/100
l/h
(mm)
**
186
110
248
118
96
157
71
79
95
250
138
333
37
25
45