Dahua IPC-HFW2831T-AS Quick Start Manual

Ir bullet network camera

Advertisement

Quick Links

IR Bullet Network Camera
Quick Start Guide
V1.0.0
ZHEJIANG DAHUA VISION TECHNOLOGY CO., LTD

Advertisement

Table of Contents
loading

Summary of Contents for Dahua IPC-HFW2831T-AS

  • Page 1 IR Bullet Network Camera Quick Start Guide V1.0.0 ZHEJIANG DAHUA VISION TECHNOLOGY CO., LTD...
  • Page 2: Foreword

    Foreword General This Quick Start Guide (hereinafter referred to be "the Guide") introduces the functions, installation and operations of the camera. Safety Instructions The following categorized signal words with defined meaning might appear in the guide. Signal Words Meaning Indicates a medium or low potential hazard which, if not avoided, could result in slight or moderate injury.
  • Page 3  All the designs and software are subject to change without prior written notice. The product updates might cause some differences between the actual product and the Guide. Please contact the customer service for the latest program and supplementary documentation. ...
  • Page 4: Important Safeguards And Warnings

    Important Safeguards and Warnings Electrical safety  All installation and operation should conform to your local electrical safety codes.  The power source shall conform to the Safety Extra Low Voltage (SELV) standard, and supply power with rated voltage which conforms to Limited power Source requirement according to IEC60950-1.
  • Page 5 protection effect.  It is recommended connect the grounding hole to the ground to enhance the reliability of the device.  Do not touch the image sensor directly (CMOS). Dust and dirt could be removed with air blower, or you can wipe the lens gently with soft cloth that moistened with alcohol. ...
  • Page 6: Regulatory Information

    Regulatory Information FCC Information Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC conditions: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference.
  • Page 7: Table Of Contents

    Table of Contents Foreword ..............................I Important Safeguards and Warnings ...................... I Regulatory Information ........................... IV 1 Introduction ............................1 1.1 Cable ............................. 1 1.2 Connecting Alarm Input/output ..................... 2 2 Network Configuration.......................... 4 2.1 Initializing Device .......................... 4 2.2 Modifying Device IP Address ......................5 2.3 Logging in Web Interface ......................
  • Page 8: Introduction

    Introduction 1.1 Cable  Cable type might vary with different devices, and the actual product shall prevail.  Please waterproof all the cable joints with insulating tape and waterproof tape to avoid short circuit and water damage. For the detailed operation, see the FAQ manual. Figure 1-1 Cable list For more information about cable ports, see Table 1-1.
  • Page 9: Connecting Alarm Input/Output

    Port Port Name Function ALARM_GND Ground connection. 1.2 Connecting Alarm Input/output Alarm input/output is available on select models. Step 1 Connect alarm input device to the alarm input end of the I/O port, see Figure 1-2. Device collects different states of alarm input port when the input signal is idling and being grounded.
  • Page 10 Figure 1-3 Mode A Figure 1-4 Mode B Step 3 Log in web interface, and configure alarm input and alarm output in alarm setting. The alarm input in the web interface is corresponding to the alarm input end of the ...
  • Page 11: Network Configuration

    Network Configuration Device initialization and IP setting can be finished with the "ConfigTool" or in web interface. For more information, see the WEB operation manual.  Device initialization is available on select models, and it is required at first use and after device is being reset.
  • Page 12: Modifying Device Ip Address

    All the devices found in the network segment are listed. Step 5 Select one or several devices which Status are Uninitialized, and then click Initialize. The Device initialization interface is displayed. Step 6 Select the devices that need initialization, and then click initialize. The password setting interface is displayed.
  • Page 13: Logging In Web Interface

    Step 3 Select the devices which IP addresses need to be modified, and then click Modify IP. The Modify IP Address interface is displayed. See Figure 2-3. Figure 2-3 Modify IP Address interface Step 4 Select Static mode and enter start IP, subnet mask and gateway. IP addresses of multiple devices will be set to the same if you select Same IP.
  • Page 14 Figure 2-4 Main interface Network Configuration 7...
  • Page 15: Installation

    Installation 3.1 Packing List  The tool required for the installation such as electric drill is not provided in the packing.  The operation manual and related tool are contained in the disk or the QR code, and the actual packing shall prevail. 3.2 Dimension Following figures are for reference only, the actual product shall prevail.
  • Page 16: Installing Device

    3.3 Installing Device 3.3.1 Installation method Wall-mounted Pole-mounted Angle-mounted Ceiling-mounted 3.3.2 Installing SD Card (Optional)  SD card slot is available on select models.  Please disconnect the power from the device before installing the SD card.  Press the reset button for 10 seconds to reset the device. Installation 9...
  • Page 17: Attaching Device

    3.3.3 Attaching Device Make sure the mounting surface is strong enough to hold at least three times of the device weight. Cable going through the mounting surface Installation 10...
  • Page 18 Cable going through the side cable tray Installation 11...
  • Page 19: Installing Waterproof Connector

    3.3.4 Installing Waterproof Connector This part is only needed when there is waterproof connector come with the device and the device is used outdoor. 3.3.5 Adjusting Angle Installation 12...
  • Page 20: Adjusting Focal Length

    3.3.6 Adjusting Focal Length Installation 13...
  • Page 21 【社会的安全 我们的责任】 SOCIAL SECURITY IS OUR RESPONSIBILITY Zhejiang Dahua Vision Technology Co., Ltd Address:No.1199 Bin’an Road, Binjiang District, Hangzhou, PRC. Postcode: 310053 Tel: +86-571-87688883 Fax: +86-571-87688815 Email:overseas@dahuatech.com Website: www.dahuasecurity.com...

This manual is also suitable for:

Ipc-hfw2231s-s-0280bIpc-hfw2831t-zs

Table of Contents