PANE L I NS TA L L AT I O N

Custom Panels

For overlay and flush inset applications, custom door and
grille panels must be installed. The panel size is critical for
a proper fit. To verify panel requirements and dimensions,
refer to the Sub-Zero Design Guide at subzero.com/specs.
Flush inset applications require a
IMPORTANT NOTE:
minimum
1
/
"
reveal on all sides.
(13)
2
Finish all sides of the custom panels. They may be visible
when the door is open or through the window of glass door
models.
EXTER N AL D ISPEN S ER
For external dispenser models, the dispenser bezel must be
removed before the custom panels can be installed.
The bezel will accommodate a
applications and a
3
/
"
thick panel for overlay and
(19)
4
flush inset applications. Panels thicker than
be routed in the dispenser area to 1
backer and spacer panels).
To Remove the Bezel:
Lift, rotate, and remove the tray.
1
Lift and remove the grille.
2
Remove the screw from the center of the chute and
3
remove the chute.
Rotate the control panel downward and disconnect the
4
wire harness.
Remove the screws from each corner of the bezel and
5
pull the bezel forward.
TRAY
GRILLE
Tray and grille removal
1
/
"
thick panel for framed
(6)
4
3
/
"
must
(19)
4
1
/
"
(including the
(29)
8
CHUTE
Dispenser bezel removal
subzero.com | 13