1. INTRODUCTION

1. INTRODUCTION
1. INTRODUCTION
1. INTRODUCTION
The TOWER-20 PG2 is a 2-way, wireless outdoor digital mirror PIR detector which includes the following features:
• Patented 8 independent quad PIR detectors (Octa-QUAD™) operating in true Quad configuration (patented) with true
motion recognition (TMR) processing for each of the 8 PIR detectors, as well as central motion processing that
distinguishes between moving intruders and trees and bushes in motion.
Advanced Obsidian Black Mirror
• Optimum performance even in poor weather conditions such as snow, rain, dust, wind and direct sunlight
• Tamper protection prevents opening and removal from wall
• PowerG two-way Frequency Hopping Spread Spectrum FHSS-TDMA technology - provides robustness and reliability that
is closer than ever to wired systems
• Built-in link quality indicators enable installer to check signal quality without physically approaching the control panel, thus
making installation faster and easier.
• Robust housing with recessed window.
• Smart anti masking distinguishes between masking spray and rain.
• Alarm LED is visible in sunlight.
• Automatic termination of walk-test after 15 minutes.
• Microprocessor-controlled temperature compensation.
• Immunity to pets weighing up to 18 Kg (40ib), not pet alley
• Built-in swivel bracket
2 2 2 2 . . . . INSTALLATION
INSTALLATION
INSTALLATION
INSTALLATION

2.1 Installation

A. Bracket installation (see Figure 2). Fix the bracket firmly on a stable wall or pillar. The orientation of the fixed bracket must be as parallel as
possible to the surveyed ground surface.
B. Adjust the detector's horizontal and vertical angles (see Figure 3), according to the surveyed ground surface. The vertical angle indicator
position for various installation height and coverage distance combinations is detailed in Table 1 (the information refers to a relatively flat
surveyed area. Verify the vertical adjustment by walk-test).
C. Fasten the detector to the bracket (see Figure 2 step 4).
Table 1 - Vertical Adjustment Reference
Mounting Height
2m / 6.7ft
-
3.0m / 10 ft
1
2.5m / 8 ft
1
2.0m / 7 ft
2
1.5m / 5 ft
Correct
Installation
Incorrect
Installation
A. Mark drilling point
D. Fasten
Note: The 2 screw holes enable adjustment
of the bracket on the wall, if needed, following
the walk test.
D-304046 TOWER-20 PG2 Installation Instructions
20 PG2
20 PG2
20 PG2
TM
optics (patent pending).
Coverage Distance
4m / 13ft
6m / 20ft
1
2
1
2
2
3
3
4
B. For wall tamper
E. Three long screws
10m / 33 ft
8m / 26ft
2
3
3
4
4
5
5
-
Figure 2 - Installation
Installation Instructions
12m / 39 ft
3
4
5
-
C. Drill
F. Two short screws
Figure 1.
General View
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Visonic TOWER-20 PG2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tyco Visonic TOWER-20 PG2

  • Page 1 TOWER TOWER- - - - 20 PG2 20 PG2 TOWER TOWER 20 PG2 20 PG2 PowerG, Wireless High-security PIR Motion Outdoor Installation Instructions Mirror Detector with Anti-masking 1. INTRODUCTION 1. INTRODUCTION 1. INTRODUCTION 1. INTRODUCTION The TOWER-20 PG2 is a 2-way, wireless outdoor digital mirror PIR detector which includes the following features: •...
  • Page 2 HORIZONTAL ADJUSTMENT (-45° ° ° ° to +45° ° ° ° ) VERTICAL ADJUSTMENT (0° ° ° ° to -10° ° ° ° in 2.5° ° ° ° clicks / steps) COVER CLOSURE 1. Release locking 2. Adjust 3. Lock 4.
  • Page 3 2.2 Battery Insertion It is recommended to perform the first batteries insertion on a flat surface (see Figure 4). After battery insertion, the LED will flash for 60 seconds and then the detector will enter a 15 minutes' local diagnostic mode. A.
  • Page 4 2.4. Configuring the Detector Parameters DEVICE SETTINGS Enter the menu and follow the configuration instructions for the TOWER-20 PG2 PIR detector as described below. Option Configuration Instructions ALARM LED Define whether or not to activate the alarm LED indication. Optional settings: ON (default) and OFF. •...
  • Page 5 A. LED B. Enroll button C. Tamper switch Figure 5. Tower-20 PG2 3. COMPLIANCE WITH STANDARDS Europe (CE): EN 300220, EN 301489, EN 60950, EN 50130-4, EN 50130-5, EN 50131-2-2, EN 50131-6, Compliance with Standards EN 50131-1 Grade 3 Class 4 The TOWER-20 PG2 is compatible with the RTTE requirements - Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999 and EN50131-1 Grade 2 Class IV.
  • Page 6 APPENDIX: APPENDIX: SPECIFICATIONS APPENDIX: APPENDIX: SPECIFICATIONS SPECIFICATIONS SPECIFICATIONS OPTICAL At least 12 m (40 ft) / 90° Black Mirror Max. Coverage 8 independent quad PIR detectors operating in true Quad configuration Detector Technology A. Top view B. Side view of each detector Figure 6.

Table of Contents