Split pair transducers: Extension cables fitted between the transducer and
the 'Y' cable must be fitted in equal length pairs (i.e.: each transducer's final
cable length must be the same).
12.2 SideVision, DownVision and CPT-S
transducer connection
SideVision™, DownVision™ and CPT-S transducers can be connected to the
display's RV/RVM Transducer connection using the RV 25-pin to DV 9-pin
adaptor cable (part number: A80490).
Example DownVision™ transducer connection
1.
Display's RV/RVM Transducer 25-pin connector.
2. RV 25-pin to DV 9-pin adaptor cable (part number: A80490).
3. Transducer (DownVision™ transducer illustrated).
For a list of compatible SideVision™ transducers refer to:
p.23 — SideVision™ transducers
For a list of compatible DownVision™ transducers refer to:
p.24 — DownVision™ transducers
For a list of compatible CPT-S transducers refer to:
p.24 — CPT-S conical beam transducers
68
DownVision™ transducer extension cable
For best performance, cable runs should be kept to a minimum. However, for
some installations it may be necessary to extend the transducer cable.
• A 4 m (13.1 ft) Transducer extension cable (Part number: A80273) is
available.
• It is recommended that only one cable extension is used.
12.3 CHIRP transducer connection
CHIRP transducers can be connected directly to the display's 11-pin 1kW
Transducer connection. B75 & B175 transducers require an operation cable
(part number: A80328).
Example CHIRP transducer connection
1.
Display's 1kW Transducer 11–pin connector.
2. Operation cable (part number: A80328) is required for B75 & B175
transducers.
3. CHIRP transducer.
For a list of compatible CHIRP transducers refer to:
p.24 — CHIRP transducers