Example NMEA 0183 version 2 /3 device connection using the Actisense®
NGW-1 converter
1.
Device NMEA 0183 wires.
2. NMEA 2000 to NMEA 0183 converter (e.g. Actisense® NGW-1 converter,
A80721).
3. SeaTalkng ™ (female) to DeviceNet (female) adaptor cable (e.g. A06045
or A06075).
4. SeaTalkng ™ network (requires dedicated 12 V dc power supply).
5. NMEA 0183 wire connections. It is recommended that wire connections
are made using crimps and then insulated using insulation tape.
Example NMEA 0183 version 2 /3 device connections
Converter signal (wire color)
TX/OUT A+ (White)
TX/OUT B- (Blue)
RX/IN A+ (Red)
RX/IN B- (Black)
Shield/Screen
Network connections
NMEA 0183 device signal
RX/IN A+
RX/IN B-
TX/OUT A+
TX/OUT B-
Vessel Ground
If your NMEA 0183 device is a version 1 device (i.e.: it only has 3 NMEA 0183
wires), the connection will differ from that described above. Please see
below for alternative wiring:
Example NMEA 0183 version 1 receiving device connections
Converter signal (wire color)
TX/OUT A+ (White)
TX/OUT B- (Blue)
Shield/Screen
Example NMEA 0183 version 1 transmitting device connections
Converter signal (wire color)
RX/IN A+ (Red)
RX/IN B- (Black)
Shield/Screen

11.4 Network connection

The display can be connected to compatible network products by connecting
a network cable between the product and one of the NETWORK connectors
located on the rear of the display. Alternatively, the display can be connected
to a network switch, e.g.: RNS-5, or the YachtSense ™ Link marine router.
Receiving NMEA 0183 device
signal
RX/IN
NOT CONNECTED
Vessel Ground
Transmitting NMEA 0183 device
signal
TX/OUT
Vessel Ground
Vessel Ground