GAS MAINTENANCE – RECOMMENDED ANNUAL ROUTINE
In order for your Regency appliance to continue to provide comfort to your home, periodic
maintenance must be performed to ensure it is operating at peak efficiency. The items in the list
should be checked by a licensed gas service technician during the annual service check. Your
unit may require more frequent maintenance checks if you notice any changes in how it operates.
Operational changes to look for can include, but are not limited to, extended start up time,
residue/carbon build up, etc. Should any of these or other conditions arise, discontinue use and
schedule a service check with your local licensed gas technician. The list below shows items your
licensed service technician will need to check and service at least annually.
CLEAN
Burner ports & burner air shutter
•
Log set
•
Pilot orifices
•
Pilot hood (Vented)
•
Flame sensor (electronic ignition models)
•
Flame electrode
•
Burner orifice
•
Thermocouple (Vent free model)
•
Thermopile (millivolt models)
•
CHECK
Voltage on thermopile (millivolt vented models)
•
Ohms reading on flame sense (electronic ignition vented models)
•
Inlet/outlet fuel pressures as per rating plate
•
Voltage/ohms readings on gas valve
•
Voltage on thermocouple (Vent free)
•
Ensure pilot is fully engulfing the thermopile and flame sensor (Millivolt/electronic Ignition
•
vented)
•
Ensure pilot is fully engulfing thermocouple (Vent free only)
GAS LEAK TESTS
Check main gas line connection to valve
•
Check shut off valve connections
•
Check connection at gas valve outlet
•
Check connection at main burner orifice
•
Check pilot fuel line at valve and at pilot assembly
•
40
FPI Fireplace Products International LTD |6988 Venture St, Delta BC Canada V4G 1H4
INSPECT
Pilot assembly
•
Burner
•
Firebox
•
Venting
•
Batteries (remote handheld,
•
remote receiver, ignition module,
change as needed)
Burner media (change as needed)
•
Air shutter setting (Vent free
•
model)
Wiring
•