Download Print this page
Federal Signal Corporation Global G-SPA Series Quick Start Manual

Federal Signal Corporation Global G-SPA Series Quick Start Manual

Amplified speaker
Hide thumbs Also See for Global G-SPA Series:

Advertisement

Quick Links

Global Series Model G-SPA
Amplified Speaker for Use in
Hazardous Conditions
25500188 Rev B8 0523
Limited Warranty: This product's limited warranty can be found at www.fedsig.com/SSG-Warranty
SAFETY MESSAGES TO INSTALLERS AND USERS
It is important to follow all instructions shipped with this product. This amplified speaker is to be installed by a trained
electrician who is thoroughly familiar with and will follow all applicable national and local codes in the country of use.
This amplified speaker should be considered a part of the warning system and not the entire warning system.
The selection of the mounting location for the amplified speaker, its controls, and the routing of the wiring are to
be accomplished under the direction of the facilities engineer and the safety engineer. Listed below are some other
important safety instructions and precautions you should follow:
Read and understand all instructions before installing or operating this equipment.
To avoid electrical shock hazards, do not connect wires when power is applied. Failure to observe this warning may
lead to serious injury or death.
Never alter the unit in any manner. Safety in hazardous locations may be endangered if additional openings or other
alterations are made in units specifically designed for use in these locations.
Do not connect this amplified speaker to the system when power is on.
All effective warning speakers produce loud sounds, which may cause, in certain situations, permanent hearing
loss. Take appropriate precautions such as hearing protection. The device should be installed far enough away from
potential listeners to limit their exposure while still maintaining its effectiveness.
After installation, ensure that all threaded joints are properly tightened.
After installation, test the amplified speaker system to ensure that it is operating properly
Keep the unit tightly closed when in operation.
After testing is complete, provide a copy of this instruction sheet to all personnel.
Brass inserts have the potential to store a charge when they are not plugged. Consideration should be taken to
prevent these from becoming a sparking hazard.
Establish a procedure to routinely check the amplified speaker system for proper activation and operation.
This equipment is suitable for use in Class I, Division 2, Groups A, B, C, D; Class II, Division 2, Groups F and G; Class
III or non-hazardous locations only.
WARNING - EXPLOSION HAZARD: Do not disconnect while the circuit is live or unless the area is known to be free
of ignitable concentrations.
WARNING - EXPLOSION HAZARD: Do not remove or replace the fuse when energized.
The purchaser should make the manufacturer aware of any external effects or aggressive substances to which the
equipment may be exposed.
Failure to follow all safety precautions and instructions may result in property damage, serious injury, or death to you or
others.
With respect to the potential electrostatic charging hazard as mentioned in the certificate "Specific Conditions of Use,"
under normal conditions of use, these devices are for fixed installations and not generally in contact with people. The risk
of ignition is low. In addition, maintenance, cleaning, and extreme environmental factors (e.g., high velocity dust-laden
atmospheres or high-pressure steam) should be taken into account by the end user using local Explosive Atmosphere
(Ex) Electrical installation design, selection, inspection, and maintenance Codes and Standards. Cleaning of the devices
should be done only with a damp cloth.
:

Advertisement

loading

Summary of Contents for Federal Signal Corporation Global G-SPA Series

  • Page 1 Global Series Model G-SPA Amplified Speaker for Use in Hazardous Conditions 25500188 Rev B8 0523 Limited Warranty: This product’s limited warranty can be found at www.fedsig.com/SSG-Warranty SAFETY MESSAGES TO INSTALLERS AND USERS It is important to follow all instructions shipped with this product. This amplified speaker is to be installed by a trained electrician who is thoroughly familiar with and will follow all applicable national and local codes in the country of use.
  • Page 2: Specific Conditions Of Use

    Certification Certificate Nos: • ATEX Cert No.: Baseefa15ATEX0155X • IECEx Cert No.: IECEx BAS 15.0104X • UKEX Cert No. SGS23UKEX0086X • ATEX coding: II 2 G D Protection: • Ex db IIB T5 Gb or Ex db e IIB T5 Gb •...
  • Page 3 A note about combination fixtures: If the product is Ex db marked only, it is for use in gas atmospheres. If the product is Ex db e marked, it uses the increased-safety terminal enclosures and is only for gas atmospheres. If the product is Ex tb marked, it is for installation in dust atmospheres.
  • Page 4: Wiring The Device

    To maintain the flameproof integrity of the enclosure, DO NOT damage the cover or threads while disassembling or reassembling the unit. • Painting and surface finishes, other than those applied by Federal Signal Corporation, are not permitted. Federal Signal signaling.fedsig.com...
  • Page 5 • Cable termination should be in accordance with the specifications that apply to the application. Federal Signal recommends that all cables and cores be fully identified. • Ensure that only the correct, equipment-certified glands are used and that the assembly is shrouded and correctly earthed.
  • Page 6 Figure 6 Ex d in/out PCB connections (25 V 25 V AUDIO JUMPER VOLTAGE SELECTOR EARTH 25 V AUDIO PASSTHOUGH Wiring the Ex d Models To wire the Ex d flameproof amplified speaker: Unscrew the M3 hex set screw on the side of the housing one full turn. Remove the cover from the housing by turning the cover counterclockwise.
  • Page 7 Connect the negative (–) audio source to the terminal block position marked AUD-. Adjusting the Sound Pressure and Audio Input (Ex d) Sound Pressure: See Figure 7. The 3/4-turn VR1 potentiometer on the PCB is factory set to the maximum sound pressure level (MAX).
  • Page 8 This section has wiring instructions for the three increased safety models: G-SPA 120 Vac, G-SPA 220-240 Vac, and G-SPA 24 Vdc. Ex de units are supplied with a six-pole, spring-tension clamp-style terminal block. The maximum wire gauge is 4.0 mm (12 AWG).
  • Page 9 120 Vac operation Connect the line (hot) power source wire to the position marked L1/+ on the terminal block. Connect the neutral (common) power source wire to the position marked L2/- on the terminal block. Connect the ground wire to the position marked on the terminal block. Connect the positive (+) audio source wire to the position marked Aud + on the terminal block.
  • Page 10: Maintenance And Service

    • Check the amplified speaker periodically to ensure that the effectiveness of the device has not been reduced because it has been clogged with a foreign substance or because objects have been placed in front of it. • Never alter the unit in any manner. Safety of the unit may be affected if additional openings or other alterations are made to the internal components or housing.
  • Page 11: Replacement Parts

    Replacement Parts Contact the factory for spare parts availability and part numbers. Typical spare parts are listed below. Due to certification, certain component parts are not available for field replacement. Units with this type of damage must be either replaced entirely or returned to Federal Signal for service. Table 1 Replacement Part Description Part Number...
  • Page 12 2645 Federal Signal Drive, University Park, Illinois 60484 Additional translations available at signaling.fedsig.com Traducciones adicionales disponibles en signaling.fedsig.com Customer Support 1-800-344-4634+1-708-534-4756, iordersup@fedsig.com Technical Support 1-800-755-7621+1-708-587-3587, signalsupport@fedsig.com signaling.fedsig.com...