SPECIFICATIONS
General Data
Cooling
Gross Cooling Capacity - Btuh
Performance
Net Cooling Capacity - Btuh
1
AHRI Rated Air Flow - cfm
Refrigerant
Environ™ Coil System
Charge
Environ™ Coil System
with Humiditrol®
Conventional Fin/Tube
Coil Option
Conventional Fin/Tube
With Humiditrol
Electric Heat Available
Compressor Type (number)
Outdoor Coils
Net face area (total) - sq. ft.
Environ
(Fin/Tube)
Outdoor
Coil Fans
Indoor
Net face area (total) - sq. ft.
Coil
Drain connection - Number and size
3 Indoor
Blower and
Maximum usable motor output (US
Drive
Selection
Blower wheel nominal diameter x width - in.
Filters
Electrical characteristics
NOTE - Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction.
AHRI Certified to AHRI Standard 340/360; 95°F outdoor air temperature and 80°F db/67°F wb entering evaporator air; minimum external duct static pressure.
1
Integrated Energy Efficiency Ratio certified and tested according to AHRI Standard 340/360.
2
Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of
3
motors furnished are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within
the service factor limitations outlined on the motor nameplate.
NOTE – Units equipped with MSAV
Nominal Tonnage
Model Number
Efficiency Type
Blower Type
Total Unit Power - kW
EER (Btuh/Watt)
1
IEER (Btuh/Watt)
2
Refrigerant Type
Circuit 1
Circuit 2
Circuit 1
Circuit 2
Circuit 1
Circuit 2
Circuit 1
Circuit 2
®
Number of rows
Fins per inch
Motor - (No.) hp
Motor rpm
Total Motor watts
Diameter - (No.) in.
Number of blades
Total Air volume - cfm
Tube diameter - in.
Number of rows
Fins per inch
Expansion device type
Nominal motor output
Only)
Motor - Drive kit number
Type of filter
Number and size - in.
(Multi-Stage Air Volume) option are limited to a motor service factor of 1.0.
®
7.5 Ton
7.5 Ton
LCH092H4B
LCH092H4M
High
High
Constant Air
MSAV® (Multi-
Volume CAV
Stage Air Volume)
93,000
93,000
90,000
90,000
3000
2800
7.5
7.5
12.7
12.7
13.0
14.0
R-410A
R-410A
6 lbs. 13 oz.
6 lbs. 13 oz.
7 lbs. 2 oz.
7 lbs. 2 oz.
6 lbs. 13 oz.
6 lbs. 13 oz.
7 lbs. 2 oz.
7 lbs. 2 oz.
12 lbs. 14 oz.
12 lbs. 14 oz.
11 lbs. 3 oz.
11 lbs. 3 oz.
16 lbs. 6 oz.
16 lbs. 6 oz.
11 lbs. 3 oz.
11 lbs. 3 oz.
7.5, 15, 22.5, 30 & 45 kW
Scroll (2)
Scroll (2)
28.0 (29.33)
28.0 (29.33)
1 (3)
1 (3)
20 (20)
20 (20)
(2) 1/3
(2) 1/3
1075
1075
800
800
(2) 24
(2) 24
3
3
8800
8800
12.78
12.78
3/8
3/8
4
4
14
14
(1) 1 in. NPT coupling
Balance port TXV, removable head
2.3 hp, 3.45 hp, 5.75 hp
Kit 1 590-890 rpm (std. and high efficiency)
Kit 2 800-1105 rpm (std. and high efficiency)
Kit 3 795-1195 rpm (std. and high efficiency)
Kit 4 730-970 rpm (std. efficiency)
Kit 5 940-1200 rpm (std. efficiency)
Kit 6 1015-1300 rpm (std. efficiency)
Kit 7 730-970 rpm (high efficiency)
Kit 8 940-1200 rpm (high efficiency)
Kit 9 1015-1300 rpm (high efficiency)
Kit 10 900-1135 rpm (std. efficiency)
Kit 11 1040-1315 rpm (std. efficiency)
Kit 12 1125-1425 rpm (std. efficiency)
(1) 15 X 15
(1) 15 X 15
208/230V, 460V or 575V - 60 hertz - 3 phase
Page 6
8.5 Ton
LCH102H4B
High
Constant Air
Volume CAV
103,800
100,000
3400
8.1
12.4
12.9
R-410A
6 lbs. 8 oz.
6 lbs. 15 oz.
6 lbs. 8 oz.
6 lbs. 15 oz.
13 lbs. 8 oz.
12 lbs. 7 oz.
17 lbs. 0 oz.
12 lbs. 7 oz.
Scroll (2)
28.0 (29.33)
1 (3)
20 (20)
(2) 1/3
1075
800
(2) 24
3
8800
12.78
3/8
4
14
2 hp, 3 hp, 5 hp
2 hp
3 hp
5 hp
(1) 15 X 15
Disposable
(4) 20 x 25 x 2
8.5 Ton
LCH102H4M
High
MSAV® (Multi-
Stage Air Volume)
103,800
100,000
3400
8.1
12.4
14.0
R-410A
6 lbs. 8 oz.
6 lbs. 15 oz.
6 lbs. 8 oz.
6 lbs. 15 oz.
13 lbs. 8 oz.
12 lbs. 7 oz.
17 lbs. 0 oz.
12 lbs. 7 oz.
Scroll (2)
28.0 (29.33)
1 (3)
20 (20)
(2) 1/3
1075
800
(2) 24
3
8800
12.78
3/8
4
14
(1) 15 X 15