INSTALLATION
Caution: The gas cooker requires
!
a 110/120VAC electrical supply to
operate the elec-tronic ignition system.
The 6' (1.8 m) power supply cord
provided with the range is equipped
with a 3-prong, grounded plug for
protection against shock hazard. The
service should have its own 15 amp
circuit breaker.
Caution: Do not loosen the factory
!
installed nut connections which secure
the range wiring to terminal block.
Electrical failure or loss of electrical
connection may occur if these 2 nuts
are loosened or removed.
CONNECTION TO THE GAS
SUPPLY
Warning: This appliance has been
!
tested in accordance with the following
standards:
• Household Cooking Gas Appliances
[ANSI Z21.1:2018 ]
• Household Cooking Gas Appliances
[CSA 1.1:2018 ]
• Gas-fired appliances for use at high
altitudes [CSA 2.17-2017]
• It is the responsibility of the owner and
the installer to determine if additional
require-ments, such as local codes
and/or stan-dards, apply to specific
installations. In the absence of local
codes, the installation must conform
with the National Fuel Code, ANSI
Z223.1/NFPA54.
For Massachusetts Installations
1. Installation must be performed by a
qualified or licensed contractor, plumber
or gas fitter qualified or licensed by
the state, province or region where this
appliance is being installed.
2. Shut-off valve must be a "T" handle gas
cock.
3. Flexible gas connector must not be
longer than 36 inches.
• Installer show the owner where the gas
shut-off valve is located.
High Altitude Installation note
• This cooker is ETL certified for safe
operation up to an altitude of 2000 ft
without any modifications. For altitudes
between 2000-4500, please contact with
Service and request conversion with high
altitude injector kit. This product is not
intended to be used for altitudes higher
than 4500 ft.
Warning: THE CONVERSION
!
SHALL BE CARRIED OUT BY A
MANUFACTURER'S AUTHORIZED
REPRESENTATIVE, IN ACCORDANCE
WITH THE REQUIREMENTS OF THE
MANUFACTURER, PROVINCIAL, OR
TERRITORIAL AUTHORITIES HAVING
JURISDICTION AND IN ACCORDANCE
WITH THE REQUIREMENTS OF
THE CSA B149.1 OR CSA B149.2
INSTALLATION CODES .
Connect to the gas supply
Warning: This product can be converted
!
to LP Gas. Gas convertion must always
be performed by Authorized Service
Agents.
• The gas connection is located below the
back panel of the range. It is accessible
back of the range.
• Shut off main gas supply valve before
discon-necting the old range and leave
it off until the new hook-up has been
completed.
• The cooker can be installed using rigid
pipe or a CSA, cCSAus, UL International-
certified flexible metal appliance
connector. If using a flexible connector,
always use a new connector.
• Apply pipe joint compound or tape
appropriate for use with Natural gas
around all male pipe threads to prevent
leaks.
• If not already present, install gas shut